Causes: Rotation of fan was detected after the stop signal for the Scanner Unit Cooling Fan was transmitted.
Remedy: [Related parts] R1.00 - Harness between the Reader Controller PCB (UN1/J103) and the Scanner Unit Cooling Fan (FM1/J125) - Scanner Unit Cooling Fan (FM1) - Reader Controller PCB (UN1) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the Reader Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> RSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> RSRAMRES
Causes: Stop of fan was detected after rotation signal for the Scanner Unit Cooling Fan was transmitted.
Remedy: [Related parts] R1.00 - Harness between the Reader Controller PCB (UN1/J103) and the Scanner Unit Cooling Fan (FM1/J125) - Scanner Unit Cooling Fan (FM1) - Reader Controller PCB (UN1) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the Reader Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> RSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> RSRAMRES
Causes: Rotation of fan was detected after the stop signal for the DADF Cooling Fan was transmitted.
Remedy: [Related parts] R1.00 - Harness between the DADF Driver PCB (UN03/J408) and the DADF Cooling Fan 2 (FM2/J620) - DADF Cooling Fan 1 (FM1) - DADF Cooling Fan 2 (FM2) - DADF Driver PCB (UN03) [Remedy] Check/replace the related harness/cable, connector and parts.
Causes: Stop of fan was detected after rotation signal for the DADF Cooling Fan was transmitted.
Remedy: [Related parts] R1.00 - Harness between the DADF Driver PCB (UN03/J408) and the DADF Cooling Fan 2 (FM2/J620) - DADF Cooling Fan 1 (FM1) - DADF Cooling Fan 2 (FM2) - DADF Driver PCB (UN03) [Remedy] Check/replace the related harness/cable, connector and parts.
Description: SDRAM error in the Reader Controller PCB
Causes: Either an access error to SDRAM in the Reader Controller PCB or an error at data inspection was detected.
Remedy: Replace the Reader Controller PCB (UN1). [Reference] Before replacing the Reader Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> RSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> RSRAMRES
Description: Error in communication between the Finisher - Saddle Stitcher (Finisher-X1)
Causes: Communication failed between the Finisher and the Saddle Stitcher
Remedy: [Related parts] - Harnesses from the Finisher Controller PCB to the Saddle Stitcher Controller PCB - Finisher Controller PCB (PBA101) - Saddle Stitcher Controller PCB (PBA201) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] When replacing the Finisher Controller PCB, refer to "Adjustments> Adjustment when Replacing the Parts" in the Service Manual.
Description: Error in communication between the Finisher - Saddle Stitcher (Finisher-X1)
Causes: Communication failed between the Finisher and the Saddle Stitcher
Remedy: [Related parts] - Harnesses from the Finisher Controller PCB to the Saddle Stitcher Controller PCB - Finisher Controller PCB (PBA101) - Saddle Stitcher Controller PCB (PBA201) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] When replacing the Finisher Controller PCB, refer to "Adjustments> Adjustment when Replacing the Parts" in the Service Manual.
Description: a. Error in communication between the Finisher - Insertion Unit (Finisher-X1/Document Insertion Unit-N1) b. Error in communication between the Finisher and Saddle Unit (Finisher-V)
Causes: a. Communication failed between Finisher - Insertion Unit b. Communication error between the Finisher Controller PCB and the Saddle Stitcher Controller PCB was detected. (Command transmission error)
Remedy: a. STAPLE FIN-X1/BOOKLET FIN-X1 [Related parts] - Harnesses from the Finisher Controller PCB to the Insertion Unit Controller PCB - Finisher Controller PCB (PBA101) - Insertion Unit Controller PCB(PCB3) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] - When replacing the Finisher Controller PCB, refer to "Adjustment> Action on parts replacement" in the Service Manual. - When replacing the Insertion Unit Controller PCB, refer to "Adjustment> Adjustment at Time of Parts Replacement" in the Service Manual. b. STAPLE FIN-V/BOOKLET FIN-V [Related parts] - Harnesses and connectors from the Finisher Controller PCB to the Saddle Stitcher Controller PCB - Finisher Controller PCB (PCB101) - Saddle Stitcher Controller PCB (PCB201) [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Check/replace the harness and connector between the Finisher Controller PCB and the Saddle Stitcher Controller PCB. 2. Replace the Finisher Controller PCB. [Reference] When replacing the Finisher Controller PCB, refer to "Adjustment> When Replacing the Parts" in the Service Manual. 3. Replace the Saddle Stitcher Controller PCB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.