Các lỗi thường gặp

Code :
  • Code: E880-0005
  • Description: HDD cooling fan (FM21) error. When detect a failure of the power supply cooling fan
  • Remedy: Connector disconnection, a fan failure
  • Code: E905-0001
  • Description: POD deck light air assist fan error. Even when the maximum LOW interval was passed, there was no change in the signal.
  • Remedy: 1. Turn OFF and then ON the power. 2. Check or Replace the shutter 3. Check or Replace the swing sensor (PS11) 4. Check or Replace the swing motor (M3) 5. Check or Replace the deck controller PCB (UN1)
  • Code: E905-0001
  • Description: POD deck light air assist fan error. Even when the maximum LOW interval was passed, there was no change in the signal.
  • Remedy: 1. Turn OFF and then ON the power. 2. Check or Replace the shutter 3. Check or Replace the swing sensor (PS11) 4. Check or Replace the swing motor (M3) 5. Check or Replace the deck controller PCB (UN1)
  • Code: E905-0002
  • Description: POD deck pickup motor cooling fan error. The pickup motor cooling fan is not placed at LOCK ON status.
  • Remedy: Check the connector of the pickup motor cooling fan (FM4). Replace the pickup motor cooling fan. Replace the deck controller PCB.
  • Code: E905-0003
  • Description: POD deck pickup motor cooling fan error. The pickup motor cooling fan is not placed at LOCK OFF status.
  • Remedy: Check the connector of the pickup motor cooling fan (FM4). Replace the pickup motor cooling fan. Replace the deck controller PCB.
  • Code: E905-0010
  • Description: Failure of the air assist for Cassette 1 of the multicassette deck. Even when the maximum LOW interval was passed, there was no change in the signal.
  • Remedy: Displacement of the connector of the swing HP sensor (S116). Failure of the swing sensor (S116). Failure of the swing motor (M102). Failure of the deck driver PCB. Failure of the DC controller PCB in the host machine.
  • Code: E905-0011
  • Description: Failure of the air assist for Cassette 2 of the multicassette deck. Even when the maximum LOW interval was passed, there was no change in the signal.
  • Remedy: Displacement of the connector of the swing HP sensor (S216). Failure of the swing sensor (S216). Failure of the swing motor (M202). Failure of the deck driver PCB. Failure of the DC controller PCB in the host machine.
  • Code: E905-0012
  • Description: Failure of the air assist for Cassette 3 of the multicassette deck. Even when the maximum LOW interval was passed, there was no change in the signal.
  • Remedy: Displacement of the connector of the swing HP sensor (S316). Failure of the swing sensor (S316). Failure of the swing motor (M302). Failure of the deck driver PCB. Failure of the DC controller PCB in the host machine.