Description: Abnormally high temperature (detected by main thermistor)
- The main thermistor detected an abnormally high temperature (235 deg C) during temperature control.
Remedy: - Check the connector of the fixing film unit. - Replace the fixing film unit. - Replace the DC controller PCB.
Code: E001-0001
Description: Abnormally high temperature (detected by sub thermistor)
- The sub thermistor detected an abnormally high temperature (300 deg C) during temperature control.
Remedy: - Check the connector of the fixing film unit. - Replace the fixing film unit. - Replace the DC controller PCB.
Code: E002-0000
Description: Low temperature during temperature control.
- The target temperature is not reached during temperature control.
Remedy: - Check the connector of the fixing film unit. - Replace the fixing film unit. - Replace the DC controller PCB.
Code: E003-0000
Description: Abnormally low temperature (detected by main thermistor)
- After the temperature detected by the main thermistor has reached the specified value, it does not reach the specified value during initial rotation.
Remedy: - Check the connector of the fixing film unit. - Replace the fixing film unit. - Replace the DC controller PCB.
Code: E003-0001
Description: Abnormally low temperature (detected by sub thermistor)
- After the temperature detected by the sub thermistor has reached the specified value, it does not reach the specified value during initial rotation.
Remedy: - Check the connector of the fixing film unit. - Replace the fixing film unit. - Replace the DC controller PCB.
Code: E010-0000
Description: Main motor failure
- The main motor is faulty.
Remedy: - Check the connector of the main motor. - Replace the main motor. - Replace the DC controller PCB.
Code: E019-0000
Description: Waste toner full detection
- The waste toner full state was detected.
Remedy: Replace the drum unit
Code: E019-0001
Description: Waster toner full detection sensor is faulty.
- The waste toner full state was detected continuously for five or more seconds while the main motor was turning.
Remedy: - Check the connector of the waster toner full sensor. - Replace the waste toner full sensor. - Replace the DC controller PCB.