Các lỗi thường gặp

Code :
  • Code: E001-0000
  • Description: Abnormally high temperature (detected by main thermistor)
    - The main thermistor detected an abnormally high temperature (235 deg C) during temperature control.
  • Remedy: - Check the connector of the fixing film unit. - Replace the fixing film unit. - Replace the DC controller PCB.
  • Code: E001-0001
  • Description: Abnormally high temperature (detected by sub thermistor)
    - The sub thermistor detected an abnormally high temperature (300 deg C) during temperature control.
  • Remedy: - Check the connector of the fixing film unit. - Replace the fixing film unit. - Replace the DC controller PCB.
  • Code: E002-0000
  • Description: Low temperature during temperature control.
    - The target temperature is not reached during temperature control.
  • Remedy: - Check the connector of the fixing film unit. - Replace the fixing film unit. - Replace the DC controller PCB.
  • Code: E003-0000
  • Description: Abnormally low temperature (detected by main thermistor)
    - After the temperature detected by the main thermistor has reached the specified value, it does not reach the specified value during initial rotation.
  • Remedy: - Check the connector of the fixing film unit. - Replace the fixing film unit. - Replace the DC controller PCB.
  • Code: E003-0001
  • Description: Abnormally low temperature (detected by sub thermistor)
    - After the temperature detected by the sub thermistor has reached the specified value, it does not reach the specified value during initial rotation.
  • Remedy: - Check the connector of the fixing film unit. - Replace the fixing film unit. - Replace the DC controller PCB.
  • Code: E010-0000
  • Description: Main motor failure
    - The main motor is faulty.
  • Remedy: - Check the connector of the main motor. - Replace the main motor. - Replace the DC controller PCB.
  • Code: E019-0000
  • Description: Waste toner full detection
    - The waste toner full state was detected.
  • Remedy: Replace the drum unit
  • Code: E019-0001
  • Description: Waster toner full detection sensor is faulty.
    - The waste toner full state was detected continuously for five or more seconds while the main motor was turning.
  • Remedy: - Check the connector of the waster toner full sensor. - Replace the waste toner full sensor. - Replace the DC controller PCB.