Code: E100-0000

Description: BD detection PCB failure
- The BD detection PCB is faulty.
Remedy: - Check the connector of the BD detection PCB. - Replace the laser scanner unit. - Replace the DC controller PCB.

Code: E196-0001

Description: Flash ROM write/read error
- The write/read of Flash ROM in the image processor PCB is faulty.
Remedy: - Replace the image processor PCB.

Code: E196-0002

Description: PCL ROM write/read error
- The write/read of PCL ROM in the image processor PCB is faulty.
Remedy: - Replace the PCL PCB. - Replace the image processor PCB.

Code: E197-0000

Description: Printer engine communication error
- Erroneous communication between the DC controller PCB and image processor PCB was detected.
Remedy: - Check the connectors of the DC controller PCB and image processor PCB. - Replace the DC controller PCB for normal connection. - Replace the image processor PCB.

Code: E716-0000

Description: Erroneous communication with optional cassette
- Disconnection of the optional cassette was detected after power-on, detection of normal connection to the optional cassette, and start of communication.
Remedy: - Check the connectors of the optional cassette PCB and DC controller PCB. - Replace the optional cassette PCB for normal connection. - Replace the DC controller PCB.

Code: E719-0000

Description: Erroneous communication with card reader (serial communication)
- Disconnection from the card reader has been detected since communication started after confirmation of normal connection to the card reader (after power-on).
- A serial communication error has occurred. (The serial communication error cannot be recovered.)
Remedy: - Check the connectors of the card reader and image processor PCB. - Replace the card reader for normal connection. - Replace the image processor PCB.

Code: E719-0001

Description: Erroneous communication with coin vendor (serial communication)
- Disconnection from the coin vendor has been detected since communication started after confirmation of normal connection to the coin vendor (after power-on).
- A serial communication error has occurred. (The serial communication error cannot be recovered.)
Remedy: - Check the connection between the image processor PCB and serial PCB. - Check the connectors of the serial PCB and coin vendor for normal connection. - Replace the serial PCB. - Check the coin vendor. - Replace the image processor PCB

Code: E730-0000

Description: inside error of the image processor PCB (PDL system error)
- The inside of the image processor PCB is faulty.
Remedy: - Replace the image processor PCB.