Description: The rise in temperature of the fixing assembly is faulty.
The reading of the main thermistor does not reach 150 deg C within 2 min 30 sec after it has exceeded 100 deg C.
Remedy: - Check if the connector (J505) of the DC controller PCB is mounted properly and also check if the connector of the fixing assembly is mounted properly. - Check the wiring between the thermistor and the DC controller. -Check if the main thermistor is mounted properly and also check if there is no contamination. - Replace the main thermistor. - Replace the fixing heater. - Replace the AC driver PCB. - Replace the DC controller PCB. Caution You must clear the error in service mode (COPIER>FUNCTION>CLEAR>ERR).
Description: The fixing temperature is too low after a standby state.
The reading of the main thermistor is 70 deg C or lower for 2 sec or more after it has reached 100 deg C.
Remedy: - Check if the connector (J505) of the DC controller PCB is mounted properly and also check if the connector of the fixing assembly is mounted properly. - Check the wiring between the thermistor and the DC controller. -Check if the main thermistor is mounted properly and also check if there is no contamination. - Replace the main thermistor. - Replace the fixing heater. - Replace the AC driver PCB. - Replace the DC controller PCB. Caution You must clear the error in service mode (COPIER>FUNCTION>CLEAR>ERR).
Description: The fixing assembly is faulty.
The SSR used to drive the fixing heater has a short circuit (detection by hardware circuitry).
Remedy: - Replace the AC driver PCB. - Replace the DC controller PCB. Caution You will have to clear the error in service mode (COPIER>FUNCTION>CLEAR>ERR).
Description: The absence of the fixing web is detected.
The length of the fixing web that has been taken up is more than a specific value and the fixing web length sensor (PS7) has detected the absence of the web for 5 sec or more.
Remedy: - Check the position of the fixing web detection lever. - Replace the fixing web. - Replace the fixing web length sensor. - Replace the DC controller PCB. Caution After replacing the fixing web, you will have to clear the two web counters in service mode (COPIER>COUNTER>MISC>FIX-WEB and COPIER>COUNTER>DRBL-1>FIX-WEB).
Description: The rotation of the main motor is faulty.
No clock pulse arrive for 2 sec or more after the main motor drive signal (MMFG) has been generated.
Remedy: - Check if the connecter (J611, J612) of the main motor is mounted properly. - Check if the connector (J1720) of the relay PCB is mounted properly. - Replace the main motor. - Replace the relay PCB. - Replace the DC controller PCB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.