Description: Waster toner full detection sensor failure
The waste toner full state was detected continuously for five or more seconds while the main motor was turning.
Remedy: - Check the connector of the waster toner full sensor. - Replace the waste toner full sensor. - Replace the DC controller PCB.
Description: Duplex unit connection error
Disconnection of the duplex unit was detected after power-on, detection of normal connection to the duplex unit, and start of communication.
Remedy: - Check the connectors of the duplex unit and DC controller PCB. - Replace the duplex controller PCB. - Replace the DC controller PCB.
Description: Printer engine communication error
Erroneous communication between the DC controller PCB and image processor PCB was detected.
Remedy: - Check the connectors of the DC controller PCB and image processor PCB. - Replace the DC controller PCB for normal connection. - Replace the image processor PCB.
Description: Finisher communication error
Data communication could not be performed normally. It has been retried three times in vain.
Remedy: - Check the connectors of the finisher controller PCB and DC controller PCB for normal connection. - Replace the finisher controller PCB. - Replace the DC controller PCB.
Description: Offset motor or finisher controller PCB failure
Offset HP sensor failure
- The offset motor was driven for 1000 ms in the HP sensor approach direction, but the offset HP sensor did not turn on.
Remedy: - Check the connector of the offset HP sensor. - Check the connector of the offset motor. - Replace the offset HP sensor. - Replace the offset motor. - Replace the finisher controller PCB.
Description: Offset motor or finisher controller PCB failure
Offset HP sensor failure
- The offset motor was driven for 1000 ms in the HP sensor escape direction, but the offset HP sensor did not turn off.
Remedy: - Check the connector of the offset HP sensor. - Check the connector of the offset motor. - Replace the offset HP sensor. - Replace the offset motor. - Replace the finisher controller PCB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.