Code: E019-0000

Description: Waste toner full detection
The waste toner full state was detected.
Remedy: Replace the drum unit.

Code: E019-0001

Description: Waster toner full detection sensor is faulty.
The waste toner full state was detected continuously for five or more seconds while the main motor was turning.
Remedy: - Check the connector of the waster toner full sensor. - Replace the waste toner full sensor. - Replace the DC controller PCB.

Code: E052-0000

Description: Erroneous connection to duplex unit
Disconnection of the duplex unit was detected after power-on, detection of normal connection to the duplex unit, and start of communication
Remedy: - Check the connectors of the duplex unit and DC controller PCB. - Replace the duplex controller PCB. - Replace the DC controller PCB.

Code: E100-0000

Description: BD detection PCB failure
The BD detection PCB is faulty
Remedy: - Check the connector of the BD detection PCB. - Replace the laser scanner unit. - Replace the DC controller PCB.

Code: E196-0001

Description: Image processor PCB failure
Error on writing and readout ROM of image processor PCB (mainn ROM).
Remedy: - Putting the switch on/off of the power supply. - Replace the image processor PCB.

Code: E196-0002

Description: Image processor PCB failure
Error on writing and readout ROM of image processor PCB (option ROM).
Remedy: - Putting the switch on/off of the power supply. - Replace the image processor PCB.

Code: E197-0000

Description: Printer engine communication error
Erroneous communication between the DC controller PCB and image processor PCB was detected.
Remedy: - Check the connectors of the DC controller PCB and image processor PCB. - Replace the DC controller PCB for normal connection. - Replace the image processor PCB.

Code: E261-0000

Description: Zero-cross signal error
If failed to detect zero-cross signal cycle of the power supply when initializing. When the input of the zero-signal failed continuously for three seconds while controlling the temperature adjustment.
Remedy: - Replace the power supply PCB. - Replace the DC controller PCB.