Description: The HDD coding key is faulty.
The SRM/PCB is faulty. The battery has become exhausted, leading to loss of SRAM contents.
Remedy: Try step 1); if it fails, try step 2). 1) Turn off and then back on the power switch to generate the key once again. 2) If the same error still continues, replace the board on which the SRAM is mounted. (Keep in mind that doing so will lead to loss of all user data.)
Description: An error has occurred in communication between the fax control PCB (2-line) and main controller PCB.
An attempt to set mode for the fax device has failed.
Remedy: 1. Check the connection of the cable between the fax control PCB (2-line) and the main controller PCB. 2. Replace the ROM DIMM of the fax control PCB (2-line). 3. Replace the fax control PCB (2- line). 4. Replace the main controller PCB.
Description: There is an error in the initialization of the IPC.
When the main power is turned on, the communication IC (IPC) on the DC controller PCB cannot be initialized.
Description: There is an error in the IPC communication.
The occurrence of an error has been recorded in the error register of the IPC chip 4 times or more within 1.5 sec.
Description: There is an error in the IPC communication.
The occurrence of an error has been recorded in the error register of the IPC chip 4 times or more within 2 sec.
Remedy: Check the cable.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.