Các lỗi thường gặp

Code :
  • Code: E019-0001
  • Description: Waste toner full detection
    The waste toner full state was detected.
  • Remedy: Replace the drum unit.
  • Code: E019-0002
  • Description: Waster toner full detection sensor is faulty.
    The waste toner full state was detected continuously for five or more seconds while the main motor was turning.
  • Remedy: - Check the connector of the waster toner full sensor. - Replace the waste toner full sensor. - Replace the DC controller PCB.
  • Code: E052-0000
  • Description: Erroneous connection to duplex unit
    Disconnection of the duplex unit was detected after power-on, detection of normal connection to the duplex unit, and start of communication
  • Remedy: - Check the connectors of the duplex unit and DC controller PCB. - Replace the duplex controller PCB. - Replace the DC controller PCB.
  • Code: E100-0000
  • Description: BD detection PCB failure
    The BD detection PCB is faulty
  • Remedy: - Check the connector of the BD detection PCB. - Replace the laser scanner unit. - Replace the DC controller PCB.
  • Code: E196-0001
  • Description: Image processor PCB failure
    Error on writing and readout ROM of image processor PCB (mainn ROM).
  • Remedy: - Putting the switch on/off of the power supply. - Replace the image processor PCB.
  • Code: E196-0002
  • Description: Image processor PCB failure
    Error on writing and readout ROM of image processor PCB (option ROM).
  • Remedy: - Putting the switch on/off of the power supply. - Replace the image processor PCB.
  • Code: E197-0000
  • Description: Printer engine communication error
    Erroneous communication between the DC controller PCB and image processor PCB was detected.
  • Remedy: - Check the connectors of the DC controller PCB and image processor PCB. - Replace the DC controller PCB for normal connection. - Replace the image processor PCB.
  • Code: E500-0001
  • Description: Finisher communication error
    Data communication could not be performed normally. It has been retried three times in vain.
  • Remedy: - Check the connectors of the finisher controller PCB and DC controller PCB for normal connection. - Replace the finisher controller PCB. - Replace the DC controller PCB.