Các lỗi thường gặp

Code :
  • Code: E001-0008
  • Description: Abnormality of the fixing unit
    A break in the non-contact thermistor case The status that A/D of the non-contact thermistor case is FFh continues for 500msec.
  • Remedy: Check on connection of the thermistor, Replace the fixing unit To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
  • Code: E001-0009
  • Description: Abnormality of the fixing unit
    A short circuit in the non-contact thermistor case The status that film A/D-case A/D of the non-contact thermistor is 0C or more continues for 700msec.
  • Remedy: Replace the fixing unit To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
  • Code: E001-0010
  • Description: Abnormality of the fixing unit
    A break in the end thermistor The status that A/D of the contact thermistor case is FFh continues for 500msec
  • Remedy: Check on connection of the thermistor, Replace the fixing unit To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
  • Code: E001-0011
  • Description: Abnormality of the fixing unit
    A short circuit in the end thermistor The status that A/D of the contact thermistor case is 39h or less continues for 500msec.
  • Remedy: Check on connection of the thermistor, Replace the fixing unit To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
  • Code: E002-0002
  • Description: Insufficient temperature rise of the fixing unit
    The non-contact thermistor fails to reach 70 deg C within 180 sec after reaching 50 deg C.
  • Remedy: Check on connection of the thermistor, Replace the fixing unit To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
  • Code: E002-0003
  • Description: Insufficient temperature rise of the fixing unit
    The non-contact thermistor fails to reach 100 deg C within 180 sec after reaching 70 deg C.
  • Remedy: Check on connection of the thermistor, Replace the fixing unit To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
  • Code: E002-0004
  • Description: Insufficient temperature rise of the fixing unit
    The non-contact thermistor fails to reach 120 deg C within 180 sec after reaching 100 deg C.
  • Remedy: Check on connection of the thermistor, Replace the fixing unit To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
  • Code: E002-0005
  • Description: Insufficient temperature rise of the fixing unit
    The non-contact thermistor fails to reach 140 deg C within 180 sec after reaching 120 deg C.
  • Remedy: Check on connection of the thermistor, Replace the fixing unit To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR