Code: E315-0010

Description: Abnormality of image data
ASIC (for compression/decompression) on the image conversion PCB is faulty. Timeout error during decoding
Remedy: Check on connection of the image conversion board, Replace the image conversion board

Code: E315-0025

Description: Abnormality of image data
ASIC (for compression/decompression) on the image conversion PCB is faulty. Image data transfer error during rotation processing.
Remedy: Check on connection of the image conversion board, Replace the image conversion board

Code: E315-0028

Description: Abnormality of image data
ASIC (for compression/decompression) on the image conversion PCB is faulty. Timeout error during rotation processing
Remedy: Check on connection of the image conversion board, Replace the image conversion board

Code: E315-0034

Description: Abnormality of image data
ASIC (for scaling processing) on the image conversion PCB is faulty. Image data transfer error during scaling processing
Remedy: Check on connection of the image conversion board, Replace the image conversion board

Code: E315-0036

Description: Abnormality of image data
ASIC (for scaling processing) on the image conversion PCB is faulty. Timeout error during scaling processing
Remedy: Check on connection of the image conversion board, Replace the image conversion board

Code: E351-0000

Description: Main controller PCB error
Communication error of the main controller PCB occurs at start-up.
Remedy: Check on connection between the main controller PCB and the main controller PCB (sub) , Replace the main controller PCB, Replace the main controller PCB (sub)

Code: E400-0001

Description: Feeder communication error
Checksum error
Remedy: Check on connection between the ADF controller PCB and the main controller PCB (sub), Replace the ADF controller PCB, Replace the main controller PCB (sub)

Code: E400-0002

Description: Feeder communication error
Reception status error
Remedy: Check on connection between the ADF controller PCB and the main controller PCB (sub), Replace the ADF controller PCB, Replace the main controller PCB (sub)
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie