Description: DDI communication error
The reader controller PCB detects communication error between the main controller PCB and the reader controller PCB.
Remedy: Disconnect and then connect the reader communication cable connector, Replace the reader controller PCB, Replace the main controller PCB
Code: E744
Description: Language file/BootROM error
Remedy: Upgrade the version of the Language file
Code: E745
Description: Token ring board error
Remedy: Check on connection of the token ring board, Replace the token ring board
Code: E746-0003
Description: Option board error
The UFR PCB for other model is detected at start-up.
Remedy: Replace with an appropriate UFR PCB
Code: E746-0004
Description: Option board error
The main controller PCB (sub) for other model is detected at start-up.
Remedy: Replace with an appropriate main controller PCB (sub)
Code: E747
Description: Main controller PCB error (Image processing ASIC or memory control/communication control ASIC)
Remedy: Turn OFF and back ON the main power, Replace the main controller PCB (main)
Code: E748
Description: Main controller PCB error
Remedy: Disconnect and then connect the main controller PCB (Sub SJ/PE/R), Replace the main controller PCB (Sub SJ/PE/R), Disconnect and then connect the relay PCB (GU-short), Replace the relay PCB (GU-short), Disconnect and then connect the open interface PCB, Replace the open interface PCB, Replace the main controller PCB (main)
Code: E749-0001
Description: Restart in accordance with a change of the product configuration
The BootROM is replaced with a different type (when the PDL option is installed)
Remedy: Turn OFF and back ON the main power to recover