Description: There is an error in image data.
Device: abnormal termination error [Location to be detected] image process module (SCIP) [Detection timing] when abnormal interruption is detected after the operation has been detected
Remedy: Check connection with DDI-S cable(RCON). Replace the main controller PCB.
Code: E315-0520
Description: There is an error in image data.
Device: timeout error [Location to be detected] image process module (CMIP) [Detection timing] When there is no interruption 2 min after the operation has been started
Remedy: Check connection with DDI-S cable(RCON). Replace the main controller PCB.
Code: E315-0521
Description: There is an error in image data.
Device: abnormal termination error [Location to be detected] image process module (CMIP) [Detection timing] when abnormal interruption is detected after the operation has been detected
Remedy: Check connection with DDI-S cable(RCON). Replace the main controller PCB
Code: E315-0530
Description: There is an error in image data.
Device: timeout error [Location to be detected] image process module (JPEN) [Detection timing] when there is no interruption 2 min after the operation has been started.
Remedy: Turn OFF and then ON the power. Replace the main controller PCB if this occurs frequently.
Code: E315-0531
Description: There is an error in image data.
Device: abnormal termination error [Location to be detected] image process module (JPEN) [Detection timing] when abnormal interruption is detected after the operation has been started.
Remedy: Turn OFF and then ON the power. Replace the main controller PCB if this occurs frequently.
Code: E315-0540
Description: There is an error in image data.
Device: timeout error [Location to be detected] image process module (JPDE) [Detection timing] when there is no interruption 2 min after the operation has been started.
Remedy: Turn OFF and then ON the power. Replace the main controller PCB if this occurs frequently.
Code: E315-0541
Description: There is an error in image data.
Device: abnormal termination error [Location to be detected] image process module (JPDE) [Detection timing] when abnormal interruption is detected after the operation has been started
Remedy: Turn OFF and then ON the power. Replace the main controller PCB if this occurs frequently.
Code: E315-0550
Description: There is an error in image data.
Device: timeout error [Location to be detected] image process module (PRIP) [Detection timing] when there is no interruption 2 min after the operation has been started.
Remedy: Check connection with DDI-P cable(DCON). Replace the main controller PCB.