Các lỗi thường gặp

Code :
  • Code: E315-0511
  • Description: There is an error in image data.
    Device: abnormal termination error [Location to be detected] image process module (SCIP) [Detection timing] when abnormal interruption is detected after the operation has been detected
  • Remedy: Check connection with DDI-S cable(RCON). Replace the main controller PCB.
  • Code: E315-0520
  • Description: There is an error in image data.
    Device: timeout error [Location to be detected] image process module (CMIP) [Detection timing] When there is no interruption 2 min after the operation has been started
  • Remedy: Check connection with DDI-S cable(RCON). Replace the main controller PCB.
  • Code: E315-0521
  • Description: There is an error in image data.
    Device: abnormal termination error [Location to be detected] image process module (CMIP) [Detection timing] when abnormal interruption is detected after the operation has been detected
  • Remedy: Check connection with DDI-S cable(RCON). Replace the main controller PCB
  • Code: E315-0530
  • Description: There is an error in image data.
    Device: timeout error [Location to be detected] image process module (JPEN) [Detection timing] when there is no interruption 2 min after the operation has been started.
  • Remedy: Turn OFF and then ON the power. Replace the main controller PCB if this occurs frequently.
  • Code: E315-0531
  • Description: There is an error in image data.
    Device: abnormal termination error [Location to be detected] image process module (JPEN) [Detection timing] when abnormal interruption is detected after the operation has been started.
  • Remedy: Turn OFF and then ON the power. Replace the main controller PCB if this occurs frequently.
  • Code: E315-0540
  • Description: There is an error in image data.
    Device: timeout error [Location to be detected] image process module (JPDE) [Detection timing] when there is no interruption 2 min after the operation has been started.
  • Remedy: Turn OFF and then ON the power. Replace the main controller PCB if this occurs frequently.
  • Code: E315-0541
  • Description: There is an error in image data.
    Device: abnormal termination error [Location to be detected] image process module (JPDE) [Detection timing] when abnormal interruption is detected after the operation has been started
  • Remedy: Turn OFF and then ON the power. Replace the main controller PCB if this occurs frequently.
  • Code: E315-0550
  • Description: There is an error in image data.
    Device: timeout error [Location to be detected] image process module (PRIP) [Detection timing] when there is no interruption 2 min after the operation has been started.
  • Remedy: Check connection with DDI-P cable(DCON). Replace the main controller PCB.