Description: The folding roller does not leave home position when the stapler/folder motor is driven for 1.5 sec
Causes: The folding roller home position sensor (PI12) is faulty. The stapler/folder motor (M7) is faulty. The stapler/folder clock sensor (PI14) is faulty. The finisher controller PCB is faulty.
Description: The folding roller does to return to home position when the stapler/folder motor is driven for 3.5 sec or more
Causes: The folding roller home position sensor (PI12) is faulty. The stapler/folder motor (M7) is faulty. The stapler/folder clock sensor (PI14) is faulty. The finisher controller PCB is faulty.
Description: The clock is disrupted for 1 sec or more while the stapler/folder motor is driven
Causes: The folding roller home position sensor (PI12) is faulty. The stapler/folder motor (M7) is faulty. The stapler/folder clock sensor (PI14) is faulty. The finisher controller PCB is faulty.
Description: When an image is transferred between the main controller PCB and the HDD, the main controller PCB detects a fault in control information
Causes: The wiring is faulty (short circuit, open circuit). The HDD is faulty. The DC controller PCB is faulty. The main controller PCB is faulty.
Remedy: 1. Wiring Are the connection and the cable between the connector J1017 on the main controller PCB and the connector J1551 on the HDD normal? YES: End. NO: Correct the connection/cable. 2. HDD, Main controller PCB Try replacing the HDD, and download the system software. Is the problem corrected? YES: End. NO: Replace the main controller PCB.
Description: When an image is transferred between the main controller PCB and the DC controller PCB, the DC controller PCB detects a fault in the control information
Causes: The wiring is faulty (short circuit, open circuit). The HDD is faulty. The DC controller PCB is faulty. The main controller PCB is faulty.
Remedy: 1. Wiring Are the connection and cable between the connector J122 on the DC controller PCB and the connector J1015 on the main controller PCB normal? NO: Correct the connection/cable. 2. DC controller PCB, Main controller PCB Try replacing the DC controller PCB. Is the problem corrected? YES: End. NO: Replace the main controller PCB.
Description: A mounting fault of the HDD is detected when the HDD is started up from the BOOT ROM
Causes: The wiring is faulty (short circuit, open circuit). The HDD is faulty. The main controller PCB is faulty.
Remedy: 1. Wiring Are the connection and the cable between connector J1025 of the main controller PCB and the connector J2005 of the HDD normal? NO: Correct the connector/cable. 2. System software Try re-installing the system software. Is the problem corrected? YES: End. 3. HDD, Main controller PCB Try replacing the HDD, and download the system software. Is the problem corrected? YES: End. NO: Replace the main controller PCB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.