Description: There is an abnormal rise in temperature. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
The power has been turned off and then back on without resetting the error
Remedy: - Reset the error. (COPIER>FUNCTION>CLEAR>ERR)
Description: There is an abnormal rise in temperature. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
The reading of the main thermistor is lower than 70 deg C for 2 sec or more after it has exceeded 100 deg C.
Remedy: connection and wiring. - Check the main/shutter thermistor for mounting condition. - Replace the main/shutter thermistor. - Replace the fixing heater unit. - Replace the DC controller PCB.
Description: There is an abnormal rise in temperature. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
The power has been turned off and then back on without resetting the error.
Remedy: - Reset the error. (COPIER>FUNCTION>CLEAR>ERR)
Description: The IH power supply is faulty/the IH control mechanism is faulty. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
The power has been turned off and then back on without resetting the error.
Remedy: - Reset the error. (COPIER>FUNCTION>CLEAR>ERR)
Description: The IH power supply is faulty/the IH control mechanism is faulty. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
There is a mismatch between the input voltage and the IH power supply ID.
Remedy: Replace the fixing heater power supply with one designed for the country of installation (voltage).
Description: The IH power supply is faulty/the IH control mechanism is faulty. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
The IH current is faulty. (current leakage)
Remedy: - Check the connector for any fault in connection. - Replace the fixing heater power supply. - Replace the DC controller PCB.
Description: The IH power supply is faulty/the IH control mechanism is faulty. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
The IH current is faulty. (no current)
Remedy: - Check the connector for any fault in connection. - Replace the fixing heater power supply. - Replace the DC controller PCB.
Description: The IH power supply is faulty/the IH control mechanism is faulty. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
There is an IH over-current.PCB.
Remedy: - Check the connector for any fault in connection. - Replace the fixing heater power supply. - Replace the DC controller PCB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.