Các lỗi thường gặp

Code :
  • Code: E043-0001
  • Description: There is an error in the 3.5K paper deck pickup motor, causing an error signal.
    After motor start-up, a lock state is not detected for 1 sec or more. The mechanical load such as on the feeding system is excessive.
  • Remedy: Turn off and then on the main power.
  • Code: E051-0001
  • Description: The horizontal registration home position is not detected within a specific period of time. The horizontal registration position is faulty (0003).
    The horizontal registration home position is not detected within a specific period of time.
  • Remedy: Turn off and then on the main power.
  • Code: E051-0002
  • Description: The horizontal registration home position is not detected within a specific period of time. The horizontal registration position is faulty (0003).
    The ON edge of the SUS plate is not detected during a search for home position.
  • Remedy: Turn off and then on the main power.
  • Code: E051-0003
  • Description: The horizontal registration home position is not detected within a specific period of time. The horizontal registration position is faulty (0003).
    The logical motor position differs between before and after the detection operation.
  • Remedy: Turn off and then on the main power.
  • Code: E061-0001
  • Description: At time of potential control, a specific level of potential is absent. Or, the limiter goes on.
    When forming an image, the potential is 10 V or less during initial rotation.
  • Remedy: Turn off and then on the main power.
  • Code: E061-0002
  • Description: At time of potential control, a specific level of potential is absent. Or, the limiter goes on.
    At time of potential control, the potential is 10 V or less during initial rotation
  • Remedy: Turn off and then on the main power.
  • Code: E061-0003
  • Description: At time of potential control, a specific level of potential is absent. Or, the limiter goes on.
    While the grid bias is being adjusted, a level of potential higher than the grid bias is sampled.
  • Remedy: Turn off and then on the main power.
  • Code: E061-0005
  • Description: At time of potential control, a specific level of potential is absent. Or, the limiter goes on.
    The difference in potential between dark and light areas is less than 100 V.
  • Remedy: Turn off and then on the main power.