Description: There is clogging by waste toner.
There is a waste toner feedscrew error. The output of the waste toner lock detecting switch (SW14) is '1' for more than 1 sec.
Remedy: Check the developing motor; then, turn off and then on the main power.
Description: There is an ATR error. xx=01 for Y; xx=02 for M; xx=03 for C; xx=04 for without color distinction
For INIT control (service mode INISET-*) at time of initial setup, the Sig value is lower than 62. The ATR sensor is damage or has an open circuit. The connector may have poor contact. The intermediate transfer belt may be soiled.
Remedy: Turn off and then on the main power; then, execute the intermediate transfer belt.
Description: There is an ATR error. xx=01 for Y; xx=02 for M; xx=03 for C; xx=04 for without color distinction
For INIT control (service mode INISET-*) at time of initial setup, the Ref value is lower than 62. The ATR sensor is damaged or has an open circuit. The connector may have poor contact. The intermediate transfer belt may be soiled
Remedy: Turn off and then on the main power; then, execute the intermediate transfer belt.
Description: There is an ATR error. xx=01 for Y; xx=02 for M; xx=03 for C; xx=04 for without color distinction
For INIT control (service mode INISET-*) at time of initial setup, the Ref value is lower than 62. The ATR sensor is damaged or has an open circuit. The connector may have poor contact. The intermediate transfer belt may be soiled
Remedy: Turn off and then on the main power; then, execute the intermediate transfer belt.
Description: There is an ATR error. xx=01 for Y; xx=02 for M; xx=03 for C; xx=04 for without color distinction
For INIT control (service mode INISET-*) at time of initial setup, the Sig value is 960 or higher. The ATR sensor is damaged or has an open circuit. The connector has poor contact. The opening/closing of the shutter is faulty. The intermediate transfer belt is soiled.
Remedy: Turn off and then on the main power; then, execute the intermediate transfer belt.
Description: There is an ATR error. xx=01 for Y; xx=02 for M; xx=03 for C; xx=04 for without color distinction
For INIT control (service mode INISET-*) at time of initial setup, the Ref value is 960 or higher. The ATR sensor is damaged or has an open circuit. The connector has poor contact. The intermediate transfer belt is soiled
Remedy: Turn off and then on the main power; then, execute the intermediate transfer belt.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.