Description: There is an error in the auto power-off circuit.
An open circuit is detected in the auto power-off circuit for 3 sec or more.
Remedy: - Turn on the power once again. - Check if the connector (J505) of theDC controller PCB is mounted properly. - Check if the connector (J1719) of the relay PCB is mounted properly. - Replace the relay PCB. - Replace the DC controller PCB.
Description: There is an error in the system fan/the power supply cooling fan (1 and 2).
The lock signal is detected for 5 sec or more although the power supply cooling fan (1 and 2) is being driven.
Remedy: - Check if there is no foreign material in the rotation assembly of the power supply cooling fan (1 and 2) fan. - Check if the connector (J505) of the DC controller PCB is mounted properly. - Replace the power supply cooling fan (1/2). - Replace the DC controller PCB.
Description: There is an error in the system fan/the power supply cooling fan (1 and 2).
The reading of the ambient temperature of the main controller is 80 degrees or higher.
Remedy: - Check if there is no foreign material in the rotation assembly of the system fan. - Check if the connector (J1028) of the main controller PCB is mounted properly. - Replace the sysytem fan. - Replace the main controller PCB. Caution In the case of a fault in the system fan, the data will be indicated in the form of an alarm (0008040004; ALARM-2).
Description: The rotation of the fixing assembly heat discharging fan and separation heat discharging fan is faulty.
The lock signal is detected for 5 sec or more although the fixing assembly heat discharging fan is being driven.
Remedy: - Check if there is no foreign material in the rotation assembly of the fixing assembly heat discharging fan. - Check if the connector (J503) of the DC controller PCB is mounted properly. - Replace the fixing assembly heat discharging fan. - Replace the DC controller PCB.
Description: The rotation of the fixing assembly heat discharging fan and separation heat discharging fan is faulty.
The lock signal is detected for 5 sec or more although the separation heat discharging fan is being driven.
Remedy: - Check if there is no foreign material in the rotation assembly of the separation heat discharging fan. - Check if the connector (J1112) of the reader controller PCB is mounted properly. - Replace the separation heat discharging fan. - Replace the reader controller PCB.
Description: The rotation of the drum fan is faulty.
The lock signal is detected for 5 sec or more although the drum fan is being driven.
Remedy: - Check if there is no foreign material in the rotation assembly of the drum fan. - Check if the connector (J512) of the DC controller PCB is mounted properly. - Replace the drum fan. - Replace the DC controller PCB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.