Mã lỗi Canon iRC1022 — Trang 4/7

Code: E066-0000

Description: Error in environment sensorbly
Failure in environment sensor.
Causes: Environment sensor fault, DC controller PCB assembly fault.
Remedy: - Replace environment sensor - Replace DC controller PCB

Code: E078-0000

Description: Error in primary transfer estrangement unit
Primary transfer estrangement unit does not function properly.
Causes: Terminal assembly fault, transfer roller estrangement solenoid fault, EBT unit fault, high-voltage power PCB assembly fault.
Remedy: - Replace ETB estrangement solenoid - Replace ETB unit - Terminal assembly fault (check on every contact between the terminals of each color and the high voltage PCB assembly)

Code: E100-0000

Description: Error in scanner motor, laser unit, BD
Yellow scanner assembly malfunction.
Causes: Laser scanner unit fault, DC controller PCB assembly fault.
Remedy: - Replace laser scanner unit - Replace DC controller PCB

Code: E100-0001

Description: Error in scanner motor, laser unit, BD
Magenta scanner assembly malfunction.
Causes: Laser scanner unit fault, DC controller PCB assembly fault.
Remedy: - Replace laser scanner unit - Replace DC controller PCB

Code: E100-0002

Description: Error in scanner motor, laser unit, BD
Cyan scanner assembly malfunction.
Causes: Laser scanner unit fault, DC controller PCB assembly fault.
Remedy: - Replace laser scanner unit - Replace DC controller PCB

Code: E100-0003

Description: Error in scanner motor, laser unit, BD
Black scanner assembly malfunction.
Causes: Laser scanner unit fault, DC controller PCB assembly fault.
Remedy: - Replace laser scanner unit - Replace DC controller PCB

Code: E100-0004

Description: Error in scanner motor, laser unit, BD
Failure output of a magenta BD signal
Causes: laser scanner unit fault, DC controller PCB fault.
Remedy: - Replace laser scanner unit - Replace DC controller PCB

Code: E100-0005

Description: Error in scanner motor, laser unit, BD
Failure output of a magenta BD signal
Causes: laser scanner unit fault, DC controller PCB fault.
Remedy: - Replace laser scanner unit - Replace DC controller PCB