Description: Error in activation of fixing motor
When 2.5 sec passed after activation of fixing motor, the cycle of the fixing motor speed detection signal does not become its specified value.or more.
Causes: Error in fixing motor, error in DC controller PCB.
Remedy: - Replacement of fixing motor - Replacement of DC controller PCB
Description: Error in activation of fixing motor
After the fixing motor speed detection signal became the specified value of the cycle, it exceeds the specified cycle for 2 continuous sec or more.ore.
Causes: Error in fixing motor, error in DC controller PCB.
Remedy: - Replacement of fixing motor - Replacement of DC controller PCB
Description: Error in density sensor
Cannot receive enough light when detecting image density.
Causes: Dirt on density sensor, error in density sensor, error in DC controller PCB, error in toner cartridge
Remedy: - Replacement of ETB unit - Error in high-voltage joint (Check high-voltage joint for each color, and each joint to high-voltage PCB) - Replacement of DC controller - Replacement of toner cartridge