Các lỗi thường gặp

Code :
  • Code: E194-0000
  • Description: Error in CPR sensor
    Cannot detect color displacement detection pattern, detected results fall outside the acceptable range.
  • Causes: Dirty color displacement detection sensor, color displacement detection sensor fault, DC controller PCB assembly fault, toner cartridge fault.
  • Remedy: Replace ETB unit - Terminal assembly fault (check on every contact between the terminals of each color and the high voltage PCB assembly) - Replace DC controller PCB - Replace toner cartridge
  • Code: E196-0001
  • Description: Error in DCON ROM
    Updating the ROM on the DC controller PCB assembly has been failed.
  • Causes:
  • Remedy: - Replace DC controller PCB
  • Code: E197-0000
  • Description: Internal communication error
  • Causes:
  • Remedy: - Replace DC controller PCB - Replace video controller PCB
  • Code: E198-0000
  • Description: DC controller memory malfunction
    DC controller memory malfunction.
  • Causes: DC controller PCB assembly fault.
  • Remedy: - Replace DC controller PCB assembly
  • Code: E202-0001
  • Description: Reader HP sensor fault
    Reader HP outward fault.
  • Causes: The CCD unit moves backward, but does not move to the home position.
  • Remedy: - Replace reader HP sensor. - Replace reader motor sensor. - Replace reader unit.
  • Code: E202-0002
  • Description: Reader HP sensor fault
    Reader HP homeward fault
  • Causes: The CCD unit moves forward, but does not move to the home position.
  • Remedy: - Replace reader HP sensor. - Replace reader motor sensor. - Replace reader unit.
  • Code: E225-0000
  • Description: Error in light intensity of the lamp.
    Decrease of light intensity of the lamp.
  • Causes:
  • Remedy: Replace reader unit.
  • Code: E248-0001
  • Description: EEPROM access error
    Error at EEPROM power-on
  • Causes: EEPROM data cannot be read at power-on.
  • Remedy: Replace reader unit.