Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Canon iRC2100 — Trang 14/17

Code: E625

Description: An error has occurred in the editor RAM.
Causes: The editor has an error.

Code: E626

Description: An error has occurred in the LCD of the editor.
Causes: The editor has an error.

Code: E627

Description: An error has occurred in the ASIC of the editor.
Causes: The editor ha an error.

Code: E628

Description: An error has occurred in the IPC of the editor.
Causes: The editor has an error.

Code: E629

Description: A sequential error has occurred in the editor.
Causes: The editor has an error.

Code: E677-0001

Description: DPRAM size error In communication for initialization, the DPRAM size returned by the PDL board to the host machine has an error. (The host machine is aware of the DPRAM size in advance; the DPRAM is a dual-port RAM used for communication between the host machine and the PDL board, and is mounted on the PDL board.)
Causes: The connection between the host machine and the PDL board is faulty. The system software is faulty. The hard disk is faulty. The PDL board is faulty. The system controller PCB of the host machine is faulty.

Code: E677-0002

Description: Initialization communication error In communication for initialization, the contents of communication returned by the PDL board to the host machine have an error and, therefore, communication cannot be established.
Causes: The connection between the host machine and the PDL board is faulty. The system software is faulty. The hard disk is faulty. The PDL board is faulty. The system controller PCB of the host machine is faulty.

Code: E677-0004

Description: PDL board disconnection After the connection of the PDL board is recognized at power-on, the PDL board is disconnected. During power-up, monitoring is executed at intervals of 2 min; however, if the CPU is not on (sleep state or the like), no error will be identified even if the PDL board is discontented. If the PDL board is disconnected in sleep state, the absence of the PDL board will be recognized at the start of the CPU.
Causes: The connection between the host machine and the PDL board is faulty. The system software is faulty. The hard disk is faulty. The PDL board is faulty. The system controller PCB of the host machine is faulty.
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie