Description: Drum/ITB motor error
Lock of the motor fails to be detected 3 sec or more after the motor starts to operate.
Remedy: Check on connection of the connector, Replace the motor
Code: E013-0001
Description: Error in the waste toner motor
Detects the fault in the waste toner motor
Remedy: Replace the waste toner motor.
Code: E013-0002
Description: Error in the waste toner motor
Indicates that the waste toner motor does not rotate due to the open circuit.
Remedy: Replace the waste toner motor. Replace the DC controller PCB.
Code: E015-0000
Description: Error in the registration/multifeeder motor
Indicates that the signal indicates the motor rotates with the target speed is not sent to the port after passing more than 3 sec from the startup of the motor.
Remedy: Check on connection of the connector, Replace the motor
Code: E020-0010
Description: Error in the developing assembly (toner fault: ATR error)
Indicates that the patch level is higher than the upper limit of the target although setting it as the minimum when initializing Yellow ATR.
Remedy: Clean the ATR sensor window. Check the mounting of the developing assembly. Check the ATR sensor open circuit. Replace the ATR sensor.
Code: E020-0011
Description: Error in the developing assembly (toner fault: ATR error)
Indicates that the patch level is higher than the upper limit of the target although setting it as the minimum when initializing Magenta ATR.
Remedy: Clean the ATR sensor window. Check the mounting of the developing assembly. Check the ATR sensor open circuit. Replace the ATR sensor.
Code: E020-0012
Description: Error in the developing assembly (toner fault: ATR error)
Indicates that the patch level is higher than the upper limit of the target although setting it as the minimum when initializing Cyan ATR.
Remedy: Clean the ATR sensor window. Check the mounting of the developing assembly. Check the ATR sensor open circuit. Replace the ATR sensor.
Code: E020-0013
Description: Error in the developing assembly (toner fault: ATR error)
Indicates that the patch level is higher than the upper limit of the target although setting it as the minimum when initializing Black ATR.
Remedy: Clean the ATR sensor window. Check the mounting of the developing assembly. Check the ATR sensor open circuit. Replace the ATR sensor.