Description: Insufficient temperature rise of the fixing unit at power-on
Delay in temperature rise after poweron The non-contact thermistor fails to reach 50 deg C within 180sec after power-on.
Remedy: Check on connection of the thermistor/thermo switch, Check on a break in the heater, Replace the cover switch, Replace the fixing unit, Replace the main power supply PCB, Replace the DC controller PCB To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
Description: Abnormality of the fixing unit
High temperature of the end thermistor is detected. (Hardware) The hardware detects abnormal high temperature of the end thermistor (230 deg C or higher) for 400msec continuously.
Remedy: Replace the fixing unit, Replace the main power supply PCB, Replace the DC controller PCB To recover from the error: In service mode COPIER>FUNCTION> CLEAR>ERR
Description: Abnormality of the fixing unit
High temperature of the non-contact thermistor (Software) Abnormal high temperature (250 deg C or higher) of the non-contact thermistor is detected for 500ms continuously.
Remedy: Replace the fixing unit, Replace the main power supply PCB, Replace the DC controller PCB To recover from the error: In service mode COPIER>FUNCTION> CLEAR>ERR
Description: Abnormality of the fixing unit
High temperature of the end thermistor (Software) Abnormal high temperature (220 deg C or more) of the end thermistor is detected for 500ms continuously.
Remedy: Replace the fixing unit, Replace the main power supply PCB, Replace the DC controller PCB To recover from the error: In service mode COPIER>FUNCTION> CLEAR>ERR
Description: Abnormality of the fixing unit
Large difference in temperature between end and center Difference in temperature (80 deg C or more) between the non-contact thermistor and the end thermistor is detected for 500msec continuously
Remedy: Replace the fixing unit, Replace the main power supply PCB, Replace the DC controller PCB To recover from the error: In service mode COPIER>FUNCTION> CLEAR>ERR
Description: Abnormality of the fixing unit
Foreign matter in the non-contact thermistor At the end of initial multiple rotations, difference in temperature (20 deg C or more) between the non-contact thermistor and the end thermistor is detected for 200msec continuously.
Remedy: Check on remaining paper in the fixing unit, Replace the fixing unit To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
Description: Abnormality of the fixing unit
A break in the non-contact thermistor film The status that A/D of the non-contact thermistor film is FFh continues for 500msec.
Remedy: Check on connection of the thermistor, Replace the fixing unit To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
Description: Abnormality of the fixing unit
A short circuit in the non-contact thermistor film The status that A/D of the non-contact thermistor film is 30h or less continues for 500msec.
Remedy: Replace the fixing unit To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.