Description: High voltage-related error
The measured current of the primary transfer ATVC is abnormal twice in succession.
Remedy: Check on the primary transfer roller spring, Clean the position where the primary transfer roller contacts, Replace the primary transfer roller, Replace the drum unit Check a value of COPIER> DISPLAY> MISC> DRM-LIFE, and replace the drum unit if the value is near 100 because the drum may have reached its life expectancy.
Code: E067-0110
Description: High voltage-related error
The measured voltage of the primary transfer ATVC is abnormal twice in succession.
Remedy: Turn OFF and back ON the main power
Code: E070-0001
Description: ITB HP detection error
HP of the ITB fails to be detected even after the specific period of time. Abnormality of the HP sensor, Deviation of the belt from its position to either edge, or soiling of the seal
Remedy: Clean the HP detection seal, Clean/Replace the HP sensor
Code: E070-0002
Description: ITB HP detection error
The next HP fails to be detected within the specific period of time after the HP of the ITB is detected.
Remedy: Clean the ITB back side and the drive roller
Code: E070-0003
Description: ITB HP detection error
The next HP is detected earlier than the specific period of time after the HP of the ITB is detected. The ITB is torn due to scratches, and the sensor detects the tear as a HP by mistake.
Remedy: Clean the HP detection seal, Clean/Replace the HP sensor
Code: E100-0001
Description: BD error
Speed lock of the BD speed control fails to be executed 5 sec after the laser scanner motor starts to operate.
Remedy: Check on connection between the laser scanner unit and the DC controller PCB, Check on 24V line fuse, Replace the laser scanner unit
Code: E100-0002
Description: BD error
The speed lock of the BD speed control fails while rotation of the laser scanner motor is stable.
Remedy: Check on connection between the laser scanner unit and the DC controller PCB, Check on 24V line fuse, Replace the laser scanner unit
Code: E100-0003
Description: BD error
The phase lock of the BD phase control fails while rotation of the laser scanner motor is stable.
Remedy: Check on connection between the laser scanner unit and the DC controller PCB, Check on 24V line fuse, Replace the laser scanner unit