Description: Feeder communication error
Reception interrupt error
Remedy: Check on connection between the ADF controller PCB and the main controller PCB (sub), Replace the ADF controller PCB, Replace the main controller PCB (sub)
Description: Finisher communication error
Communication error is detected between the main body and the finisher for specific times and specific period of time.
Remedy: Check on connection between the DC controller PCB and the finisher controller PCB, Replace the finisher controller PCB, Replace the DC controller PCB
Description: Finisher internal communication error Finisher-P1
Communication error between the finisher and the saddle unit
Remedy: Check on connection between the saddle stitcher controller PCB and the finisher controller PCB, Replace the finisher controller PCB, Replace the saddle stitcher controller PCB
Description: Finisher internal communication error Finisher-P1
Communication error between the finisher and the puncher unit
Remedy: Check on connection between the puncher controller PCB and the finisher controller PCB, Replace the finisher controller PCB, Replace the puncher controller PCB
Description: Finisher backup memory error
Data stored in the backup memory is abnormal.
Remedy: Check on connection between the DC controller PCB and the finisher controller PCB, Replace the finisher controller PCB, Replace the DC controller PCB
Description: Finisher backup memory error Finisher-Q1/Q3, Saddle Finisher-Q2/Q4
Abnormality of puncher unit EEPROM data