Description: High voltage-related error (Primary transfer)
The first detected current of primary transfer ATVC is the threshold or more.
Remedy: Check on the primary transfer roller spring, Clean the position where the primary transfer roller contacts, Replace the primary transfer roller, Replace the drum unit Check a value of COPIER> DISPLAY> MISC> DRM-LIFE, and replace the drum unit if the value is near 100 because the drum may have reached its life expectancy.
Description: High voltage-related error (Primary transfer)
The two detected currents of primary transfer ATVC are both the threshold or less.
Remedy: Check on the primary transfer roller spring, Clean the position where the primary transfer roller contacts, Replace the primary transfer roller, Replace the drum unit Check a value of COPIER> DISPLAY> MISC> DRM-LIFE, and replace the drum unit if the value is near 100 because the drum may have reached its life expectancy.
Description: High voltage-related error (Primary transfer)
The two detected currents of primary transfer ATVC are the same each other.
Remedy: Check on the primary transfer roller spring, Clean the position where the primary transfer roller contacts, Replace the primary transfer roller, Replace the drum unit Check a value of COPIER> DISPLAY> MISC> DRM-LIFE, and replace the drum unit if the value is near 100 because the drum may have reached its life expectancy.
Description: Error in polygon motorSpeed lock of the FG speed control fails to be executed 5 sec after the polygon motor starts to operate (Does not reach the specified speed).
Remedy: Check on connection between the laser scanner unit and the DC controller PCB, Check on 24V line fuse, Replace the laser scanner unit.