Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Canon iRC3080

Code: E001-0000

Description: Abnormality high temperature error of the fixing unit
Detect high temperature by the main thermistor (software). Software detects that the temperature detected by the main thermistor is abnormally high (above 260 deg C) for 500 ms continuously.
Remedy: Replace the fixing unit, Replace the main power supply PCB, Replace the DC controller PCB To recover from the error: In service mode COPIER>FUNCTION> CLEAR>ERR

Code: E001-0001

Description: Abnormality high temperature error of the fixing unit
Detect high temperature by the sub thermistor (software). Software detects that the temperature detected by the sub thermistor is abnormally high (above 260 deg C) for 500 ms continuously.
Remedy: Replace the fixing unit, Replace the main power supply PCB, Replace the DC controller PCB To recover from the error: In service mode COPIER>FUNCTION> CLEAR>ERR

Code: E001-0003

Description: Abnormality high temperature error of the fixing unit
Detect high temperature by the sub thermistor (hardware). Hardware detects that the temperature detected by the contact type thermistor is abnormally high (above 230 deg C).
Remedy: Replace the fixing unit, Replace the main power supply PCB, Replace the DC controller PCB To recover from the error: In service mode COPIER>FUNCTION> CLEAR>ERR

Code: E003-0000

Description: Error in the low temperature of the fixing unit
Detects the temperature detected by the main thermistor is abnormally low (below 120 deg C) for 1 sec continuously after passing 20 sec from turning ON the fixing heater.
Remedy: Check the connection of the main thermistor/thermal switch. Check open circuit of heater. Replace the cover switch. Replace the fixing unit. Replace the main power supply PCB. Replace the DC controller PCB. Clear the error in service mode: COPIER > FUNCTION > CLEAR > ERR.

Code: E003-0001

Description: Error in the low temperature of the fixing unit
Detects the temperature detected by the sub thermistor is abnormally low (below 70 deg C) for 1 sec continuously while adjusting print temperature.
Remedy: Check on connection of the sub thermistor/thermo switch, Replace the fixing unit, Check on a break in the heater, Replace the cover switch, Replace the main power supply PCB, Replace the DC controller PCB To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR

Code: E003-0002

Description: Error in the low temperature of the fixing unit
Detects the abnormally low temperature (open circuit) when turning ON the fixing heater.
Remedy: Clear the error in service mode: COPIER > FUNCTION > CLEAR > ERR.

Code: E004-0000

Description: Thermistor is not connected
During walm-up rotation, the thermistor connection signal (FUSER CNCTX) is open.
Remedy: - Confirm the cable connection - Replace the cable exchange, and established - Replace the fixing unit - Replace the DC controller PCB.

Code: E009-0001

Description: Error in pressure/release of fixing film unit
In case that the output of fixing automatic pressure phase sensor is not changed although rotating/reversing the fixing motor
Remedy: Check the pressure/release mechanism. Check the connection of the connector. Replace the motor.