Description: Error in communication of controller
There is no response when 4 sec passed since the main controller had sent the request for image output to DC controller during printing.
Remedy: Check connector, check connection of sub PCB in the controller box, check / replace DC controller PCB / main controller PCB
Code: E240-0003
Description: Error in communication of controller
The engine is activated when jam occurs.
Remedy: Check connector, check connection of sub PCB in the controller box, check / replace DC controller PCB / main controller PCB
Code: E240-0004
Description: Error in communication of controller
When 90 seconds pass as the pre-rotation end waiting
Remedy: Check connector, check connection of sub PCB in the controller box, check / replace DC controller PCB / main controller PCB
Code: E240-0005
Description: Error in communication of controller
When 90 seconds pass as the Dhalf beginning waiting
Remedy: Check connector, check connection of sub PCB in the controller box, check / replace DC controller PCB / main controller PCB
Code: E243-0000
Description: Control panel unit error
Communication between the main controller and the control panel unit is abnormal.
Remedy: Check on connection between the main controller PCB and the control panel unit
Code: E244-0000
Description: Error in connection of the flexible cable on the DC controller PCB
Error in connection of the flexible cable on the DC controller PCB (right side (1 pc.))
Remedy: Check the connection of the flexible cable, replace the DC controller PCB
Code: E244-0001
Description: Error in connection of the flexible cable on the DC controller PCB
Error in connection of the flexible cable on the DC controller PCB (left side (3 pc.))
Remedy: Check the connection of the flexible cable, replace the DC controller PCB
Code: E248-0000
Description: Backup memory error
Check error of the SRAM PCB (at start up)
Remedy: Check on connection of the SRAM PCB, Replace the SRAM PCB