Description: Insufficient temperature rise of the fixing unit at power-on
Delay in temperature rise after poweron The non-contact thermistor fails to reach 50 deg C within 180sec after power-on.
Remedy: Check on connection of the thermistor/thermo switch, Check on a break in the heater, Replace the cover switch, Replace the fixing unit, Replace the main power supply PCB, Replace the DC controller PCB To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
Code: E001-0001
Description: Abnormality of the fixing unit
High temperature of the end thermistor is detected. (Hardware) The hardware detects abnormal high temperature of the end thermistor (230 deg C or higher) for 400msec continuously.
Remedy: Replace the fixing unit, Replace the main power supply PCB, Replace the DC controller PCB To recover from the error: In service mode COPIER>FUNCTION> CLEAR>ERR
Code: E001-0002
Description: Abnormality of the fixing unit
High temperature of the non-contact thermistor (Software) Abnormal high temperature (250 deg C or higher) of the non-contact thermistor is detected for 500ms continuously.
Remedy: Replace the fixing unit, Replace the main power supply PCB, Replace the DC controller PCB To recover from the error: In service mode COPIER>FUNCTION> CLEAR>ERR
Code: E001-0003
Description: Abnormality of the fixing unit
High temperature of the end thermistor (Software) Abnormal high temperature (220 deg C or more) of the end thermistor is detected for 500ms continuously.
Remedy: Replace the fixing unit, Replace the main power supply PCB, Replace the DC controller PCB To recover from the error: In service mode COPIER>FUNCTION> CLEAR>ERR
Code: E001-0004
Description: Abnormality of the fixing unit
Large difference in temperature between end and center Difference in temperature (80 deg C or more) between the non-contact thermistor and the end thermistor is detected for 500msec continuously
Remedy: Replace the fixing unit, Replace the main power supply PCB, Replace the DC controller PCB To recover from the error: In service mode COPIER>FUNCTION> CLEAR>ERR
Code: E001-0005
Description: Abnormality of the fixing unit
Foreign matter in the non-contact thermistor At the end of initial multiple rotations, difference in temperature (20 deg C or more) between the non-contact thermistor and the end thermistor is detected for 200msec continuously.
Remedy: Check on remaining paper in the fixing unit, Replace the fixing unit To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
Code: E001-0006
Description: Abnormality of the fixing unit
A break in the non-contact thermistor film The status that A/D of the non-contact thermistor film is FFh continues for 500msec.
Remedy: Check on connection of the thermistor, Replace the fixing unit To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
Code: E001-0007
Description: Abnormality of the fixing unit
A short circuit in the non-contact thermistor film The status that A/D of the non-contact thermistor film is 30h or less continues for 500msec.
Remedy: Replace the fixing unit To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR