Code: E400-0003

Description: Feeder communication error
Reception interrupt error
Remedy: Check on connection between the ADF controller PCB and the main controller PCB (sub), Replace the ADF controller PCB, Replace the main controller PCB (sub)

Code: E490-0001

Description: Model error
Feeder for other model is detected.
Remedy: Connect an appropriate feeder

Code: E500-0001

Description: Finisher communication error
Communication error is detected between the main body and the finisher for specific times and specific period of time.
Remedy: Check on connection between the DC controller PCB and the finisher controller PCB, Replace the finisher controller PCB, Replace the DC controller PCB

Code: E503-0002

Description: Finisher internal communication error Finisher-P1
Communication error between the finisher and the saddle unit
Remedy: Check on connection between the saddle stitcher controller PCB and the finisher controller PCB, Replace the finisher controller PCB, Replace the saddle stitcher controller PCB

Code: E503-0003

Description: Finisher internal communication error Finisher-P1
Communication error between the finisher and the puncher unit
Remedy: Check on connection between the puncher controller PCB and the finisher controller PCB, Replace the finisher controller PCB, Replace the puncher controller PCB

Code: E505-0001

Description: Finisher backup memory error
Data stored in the backup memory is abnormal.
Remedy: Check on connection between the DC controller PCB and the finisher controller PCB, Replace the finisher controller PCB, Replace the DC controller PCB

Code: E505-0002

Description: Finisher backup memory error Finisher-Q1/Q3, Saddle Finisher-Q2/Q4
Abnormality of puncher unit EEPROM data
Remedy: Check on connection between the puncher controller PCB and the finisher controller PCB, Replace the finisher controller PCB, Replace the puncher controller PCB

Code: E514-0001

Description: Stack delivery error Finisher-P1
The HP sensor fails to be ON within 1500ms after the return belt starts to move to its HP.
Remedy: Check on a drive of the stack retaining roller, Replace the return belt U-turn HP sensor (SR5) , Replace the stack delivery motor (M2)