Description: Saddle rear side staple error
The stitching HP sensor fails to be OFF after the stitcher motor (rear) rotates for 0.5 sec. or more.
Remedy: Replace the stitcher motor (rear, M6S), Replace the stitching HP sensor (rear, MS5S)
Code: E5F5-0001
Description: Saddle front side staple error
The stitching HP sensor fails to be ON after the stitcher motor (front) rotates in the adverse direction for 0.5 sec. or more.
Remedy: Replace the stitcher motor (front, M7S), Replace the stitching HP sensor (front, MS7S)
Code: E5F5-0002
Description: Saddle front side staple error
The stitching HP sensor fails to be OFF after the stitcher motor (front) rotates for 0.5 sec. or more.
Remedy: Replace the stitcher motor (front, M7S), Replace the stitching HP sensor (front, MS7S)
Code: E5F6-0001
Description: Saddle paper push-on error
The paper pressure plate HP sensor fails to be ON after the paper pressure plate motor is driven for 0.3 sec. or more.
Remedy: Replace the paper pressure plate motor (M8S), Replace the paper pressure plate HP sensor (PI14S)
Code: E5F6-0002
Description: Saddle paper push-on error
The paper pressure plate HP sensor fails to be OFF after the paper pressure plate motor is driven for 80ms or more.
Remedy: Replace the paper pressure plate motor (M8S), Replace the paper pressure plate HP sensor (PI14S)
Code: E5F6-0003
Description: Saddle paper push-on error
The number of detection pulses for the paper pressure plate motor clock sensor is below the specific level.
Remedy: Replace the paper pressure plate motor (M8S), Replace the paper pressure plate motor clock sensor (PI1S)
Code: E5F6-0004
Description: Saddle paper push-on error
The paper pressure plate leading edge sensor fails to be OFF after the paper pressure plate motor is driven for 80ms or more.
Remedy: Replace the paper pressure plate motor (M8S), Replace the paper pressure plate leading edge sensor (PI15S)
Code: E5F6-0005
Description: Saddle paper push-on error
The paper pressure plate leading edge sensor fails to be ON after the paper pressure plate motor is driven for 0.3 sec. or more.
Remedy: Replace the paper pressure plate motor (M8S), Replace the paper pressure plate leading edge sensor (PI15S)