Các lỗi thường gặp

Code :
  • Code: E020-XXA8
  • Description: Drum/Developer-related error XX=01:Y XX=02:M XX=03:C XX=04:K XX=00:Any color
    In ATR control, the detected T/D ratio is upper than its upper limit (13%) 3 times in succession.
  • Remedy: Check on toner leak from toner buffer in the developing unit, Replace the ATR sensor
  • Code: E020-XXA9
  • Description: Drum/Developer-related error XX=01:Y XX=02:M XX=03:C XX=04:K XX=00:Any color
    In ATR control, the detected T/D ratio is lower than its lower limit (3%) 3 times in succession.
  • Remedy: Check on attachment of the developing unit, Replace the ATR sensor
  • Code: E021-0001
  • Description: Developing rotary error
    HP of the developing rotary fails to be detected.
  • Remedy: Check on connection of the HP sensor, between the rotary motor and the DC controller PCB, Replace the HP sensor, Replace the DC controller PCB, Replace the rotary motor
  • Code: E021-0002
  • Description: Developing rotary error
    Flag detection timing while the developing rotary rotates is too fast or too late.
  • Remedy: Check on connection of the HP sensor, between the rotary motor and the DC controller PCB, Replace the HP sensor, Replace the DC controller PCB, Replace the rotary motor
  • Code: E021-0003
  • Description: Developing rotary error
    The sensor fails to detect the flag when the developing rotary stops at the developing position.
  • Remedy: Check on connection of the HP sensor, between the rotary motor and the DC controller PCB, Replace the HP sensor, Replace the DC controller PCB, Replace the rotary motor
  • Code: E026-XX01
  • Description: Toner empty error XX=01:Y XX=02:M XX=03:C XX=04:K
    After toner runs out, toner density fails to go back to normal even if toner replacement and toner recovery have been performed 5 times or more in succession.
  • Remedy: Replace the toner container, Check on a position of the developing shutter
  • Code: E032-0001
  • Description: The counter of the NE controller fails to operate.
    A break in the count pulse signal is detected.
  • Remedy: Check on a break in the cable
  • Code: E045-0001
  • Description: OHP sensor error
    The sampling data measured during initial multiple rotations is lower than the specific level.
  • Remedy: Replace the OHP sensor