Description: The rise in temperature of the fixing unit is inadequate.
The output of the non-contact thermistor does not reach 140°C within 180 sec after it has reached 120°C.
Description: The rise in temperature of the fixing unit is inadequate.
The output of the non-contact thermistor does not reach 160°C within 180 sec after it has reached 140°C.
Description: The rise in temperature of the fixing unit is inadequate.
The output of the non-contact thermistor does not reach 180°C within 180 sec after it has reached 160°C.
Description: The rise in temperature of the fixing unit is inadequate.
The output of the non-contact thermistor does not reach 190°C within 180 sec after it has reached 180°C.
Description: The rise in temperature of the fixing unit is inadequate.
The output of the non-contact thermistor does not reach 120°C within 300 sec after power-on.
Description: The rise in temperature of the fixing unit is inadequate.
The output of the non-contact thermistor does not reach 190°C within 300 sec after it has reached 120°C.
Description: The temperature of the fixing unit is abnormally low after standby.
After standby, the reading of the non-contact thermistor remains 120°C or less for 10 sec.