Description: Controller fan error
Stoppage of the controller fan is detected for 16 sec continuously.
Remedy: Check on connection of the controller fan, Replace the controller fan
Code: E805-0001
Description: Fan error
Lock fails to be detected for 5sec continuously while the exhaust fan (front) is driven. Disconnection of the fan connector. Lock signal fails to be sent due to a fan failure.
Remedy: Check on connection of the exhaust fan (front), Replace the exhaust fan (front)
Code: E805-0002
Description: Fan error
Lock fails to be detected for 5sec continuously while the exhaust fan (rear) is driven. Disconnection of the fan connector. Lock signal fails to be sent due to a fan failure.
Remedy: Check on connection of the exhaust fan (rear), Replace the exhaust fan (rear)
Code: E806-0001
Description: Error in fan of main body
Error in delivery adhesive fan was detected
Remedy: Check the connection of delivery adhesive fan, replace it
Code: E806-0002
Description: Error in fan of main body
The drop of connector of delivery adhesive fan / the disconnection was detected
Remedy: Check the connection of delivery adhesive fan, replace it
Code: E806-0003
Description: Error in fan of main body
Error in secondary transfer exhaust fan was detected
Remedy: Check the connection of secondary transfer exhaust fan, replace it
Code: E807-0001
Description: Error in fan of process cartridge
Error in fan (front) of process cartridge was detected
Remedy: Check the connection of fan (front) of process cartridge, replace it
Code: E807-0002
Description: Error in fan of process cartridge
Error in fan (rear) of process cartridge was detected
Remedy: Check the connection of fan (rear) of process cartridge, replace it