Mã lỗi Canon iRC3380i — Trang 17/27

Code: E592-8005

Description: Puncher side registration sensor error
Light receiving voltage at the time of light emission is abnormal.
Remedy: Replace the side registration sensor 2

Code: E592-8006

Description: Puncher side registration sensor error
Light receiving voltage at the time of non-light-emission is abnormal.
Remedy: Replace the side registration sensor 2

Code: E592-8007

Description: Puncher side registration sensor error
Light receiving voltage at the time of light emission is abnormal.
Remedy: Replace the side registration sensor 3

Code: E592-8008

Description: Puncher side registration sensor error
Light receiving voltage at the time of non-light-emission is abnormal.
Remedy: Replace the side registration sensor 3

Code: E592-8009

Description: Puncher side registration sensor error
Light receiving voltage at the time of light emission is abnormal.
Remedy: Replace the side registration sensor 4

Code: E592-800A

Description: Puncher side registration sensor error
Light receiving voltage at the time of non-light-emission is abnormal.
Remedy: Replace the side registration sensor 4

Code: E593-8001

Description: Puncher shift motor error
The HP sensor fails to be OFF.
Remedy: Replace the HP sensor, Replace the puncher shift motor

Code: E593-8002

Description: Puncher shift motor error
The HP sensor fails to be ON.
Remedy: Replace the HP sensor, Replace the puncher shift motor