Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Canon iRC3480i — Trang 3/27

Code: E020-0020

Description: Error in the developing assembly (toner fault: ATR error)
Indicates that the patch level is lower than the lower limit of the target although setting it as the maximum when initializing Yellow ATR.
Remedy: Clean the ATR sensor window. Check the mounting of the developing assembly. Check the ATR sensor open circuit. Replace the ATR sensor.

Code: E020-0021

Description: Error in the developing assembly (toner fault: ATR error)
Indicates that the patch level is lower than the lower limit of the target although setting it as the maximum when initializing Magenta ATR.
Remedy: Clean the ATR sensor window. Check the mounting of the developing assembly. Check the ATR sensor open circuit. Replace the ATR sensor.

Code: E020-0021

Description: Error in the developing assembly (toner fault: ATR error)
Indicates that the patch level is lower than the lower limit of the target although setting it as the maximum when initializing Magenta ATR.
Remedy: Clean the ATR sensor window. Check the mounting of the developing assembly. Check the ATR sensor open circuit. Replace the ATR sensor.

Code: E020-0022

Description: Error in the developing assembly (toner fault: ATR error)
Indicates that the patch level is lower than the lower limit of the target although setting it as the maximum when initializing Cyan ATR.
Remedy: Clean the ATR sensor window. Check the mounting of the developing assembly. Check the ATR sensor open circuit. Replace the ATR sensor.

Code: E020-0023

Description: Error in the developing assembly (toner fault: ATR error)
Indicates that the patch level is lower than the lower limit of the target although setting it as the maximum when initializing Black ATR.
Remedy: Clean the ATR sensor window. Check the mounting of the developing assembly. Check the ATR sensor open circuit. Replace the ATR sensor.

Code: E020-0100

Description: Error in the developing assembly (toner fault: ATR error)
Measured density value of patch for Yellow is higher than the upper limit.
Remedy: Check the toner leakage from the toner buffer block within the developing assembly. Replace the patch image reading sensor.

Code: E020-0101

Description: Error in the developing assembly (toner fault: ATR error)
Measured density value of patch for Magenta is higher than the upper limit.
Remedy: Check the toner leakage from the toner buffer block within the developing assembly. Replace the patch image reading sensor.

Code: E020-0102

Description: Error in the developing assembly (toner fault: ATR error)
Measured density value of patch for Cyan is higher than the upper limit.
Remedy: Check the toner leakage from the toner buffer block within the developing assembly. Replace the patch image reading sensor.