Description: Main controller PCB error
Communication error of the main controller PCB occurs at start-up.
Remedy: Disconnect and connect the main controller PCB (sub SJ-A/ PDRM-EF-A/R-A), or replace it. Replace the main controller PCB (main).
Code: E400-0001
Description: Feeder communication error
Checksum error
Remedy: - Check the connection of the cable - Check on connection between the ADF controller PCB and the main controller PCB (sub), Replace the ADF controller PCB, Replace the main controller PCB (sub
Code: E400-0002
Description: Feeder communication error
Reception status error
Remedy: - Check the connection of the cable - Check on connection between the ADF controller PCB and the main controller PCB (sub), Replace the ADF controller PCB, Replace the main controller PCB (sub
Code: E400-0003
Description: Feeder communication error
Reception interrupt error
Remedy: - Check the connection of the cable - Check on connection between the ADF controller PCB and the main controller PCB (sub), Replace the ADF controller PCB, Replace the main controller PCB (sub
Code: E413-0001
Description: Pressure motor trouble
Pressure HP sensor OPEN