Code: E002-0002

Description: Insufficient temperature rise of fixing unit
When the fixing main thermistor fails to reach 80 deg C within the prescribed period of time after reaching 50 deg C during warm-up
Remedy: Replace the fixing belt unit. Replace the fixer and AC driver PCB. Replace the DC controller PCB 2 (MAISY). In the service mode, clear the error by selecting COPIER > FUNCTION > CLEAR > ERR.

Code: E002-0003

Description: Insufficient temperature rise of fixing unit
When the fixing main thermistor fails to reach 110 deg C within the prescribed period of time after reaching 80 deg C during warm-up
Remedy: Replace the fixing belt unit. Replace the fixer and AC driver PCB. Replace the DC controller PCB 2 (MAISY). In the service mode, clear the error by selecting COPIER > FUNCTION > CLEAR > ERR.

Code: E002-0004

Description: Insufficient temperature rise of fixing unit
When the fixing main thermistor fails to reach 130 deg C within the prescribed period of time after reaching 110 deg C during warm-up
Remedy: Replace the fixing belt unit. Replace the fixer and AC driver PCB. Replace the DC controller PCB 2 (MAISY). In the service mode, clear the error by selecting COPIER > FUNCTION > CLEAR > ERR.

Code: E002-0005

Description: Insufficient temperature rise of fixing unit
When the fixing main thermistor fails to reach 150 deg C within the prescribed period of time after reaching 130 deg C during warm-up
Remedy: Replace the fixing belt unit. Replace the fixer and AC driver PCB. Replace the DC controller PCB 2 (MAISY). In the service mode, clear the error by selecting COPIER > FUNCTION > CLEAR > ERR.

Code: E002-0006

Description: Insufficient temperature rise of fixing unit
When the fixing main thermistor fails to reach 170 deg C within the prescribed period of time after reaching 150 deg C during warm-up
Remedy: Replace the fixing belt unit. Replace the fixer and AC driver PCB. Replace the DC controller PCB 2 (MAISY). In the service mode, clear the error by selecting COPIER > FUNCTION > CLEAR > ERR.

Code: E002-0101

Description: Insufficient temperature rise of fixing unit
When the pressure main thermistor fails to reach 80 deg C within the prescribed period of time after reaching 50 deg C during warm-up
Remedy: Replace the fixing belt unit. Replace the fixer and AC driver PCB. Replace the DC controller PCB 2 (MAISY). In the service mode, clear the error by selecting COPIER > FUNCTION > CLEAR > ERR.

Code: E002-0102

Description: Insufficient temperature rise of fixing unit
When the pressure main thermistor fails to reach 100 deg C within the prescribed period of time after reaching 80 deg C during warm-up
Remedy: Replace the fixing belt unit. Replace the fixer and AC driver PCB. Replace the DC controller PCB 2 (MAISY). In the service mode, clear the error by selecting COPIER > FUNCTION > CLEAR > ERR.

Code: E003-0001

Description: Fixing unit low temperature trouble
When the fixing main thermistor has detected a temperature below 130 deg C for the prescribed period of time after standby
Remedy: Checking Disconnection of the Connector in the Thermistor Wiring. Replace the fixing belt unit. Replace the fixer and AC driver PCB. Replace the DC controller PCB 2 (MAISY). In the service mode, clear the error by selecting COPIER > FUNCTION > CLEAR > ERR