Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Canon iRC4080 — Trang 8/27

Code: E020-xx70

Description: Concerning the first two digits of the details code in xx12 to xxD0 xx=01: Y xx=02: M xx=03: C xx=04: Bk
Incorrect developer density target value which was set when the new drum unit was installed (value is extremely low)
Remedy: Replace the drum unit (check its connections).

Code: E020-xx80

Description: Concerning the first two digits of the details code in xx12 to xxD0 xx=01: Y xx=02: M xx=03: C xx=04: Bk
Density value is extremely high for the ITB surface reflectivity when the new drum unit was installed. SALT sensor trouble.
Remedy: Replace the SALT sensor (clean the sensor window). Replace the drum unit (check its connections). Replace the ITB (clean it).

Code: E020-xx81

Description: Concerning the first two digits of the details code in xx12 to xxD0 xx=01: Y xx=02: M xx=03: C xx=04: Bk
Density value is extremely low for the ITB surface reflectivity when the new drum unit was installed. SALT sensor trouble. Dirty ITB.
Remedy: Replace the SALT sensor (clean the sensor window). Replace the drum unit (check its connections). Replace the ITB (clean it).

Code: E020-xx83

Description: Concerning the first two digits of the details code in xx12 to xxD0 xx=01: Y xx=02: M xx=03: C xx=04: Bk
Trouble in detected ITB surface reflectivity rate (value is extremely high)
Remedy: Replace the ITB (clean it).

Code: E020-xxA0

Description: Concerning the first two digits of the details code in xx12 to xxD0 xx=01: Y xx=02: M xx=03: C xx=04: Bk
Measured value of the detected developer density is extremely low. Trouble in the ATR sensor. Trouble in the drum unit.
Remedy: Replace the drum unit (check its connections).

Code: E020-xxB0

Description: Concerning the first two digits of the details code in xx12 to xxD0 xx=01: Y xx=02: M xx=03: C xx=04: Bk
T/D ratio has dropped due to the drum unit end-of-life. Broken or disconnected wire in the ATR sensor.
Remedy: Replace the drum unit (check its connections).

Code: E020-xxB2

Description: Concerning the first two digits of the details code in xx12 to xxD0 xx=01: Y xx=02: M xx=03: C xx=04: Bk
T/D ratio is extremely high compared with when the new drum unit was installed.
Remedy: Replace the drum unit (check its connections).

Code: E020-xxB2

Description: Concerning the first two digits of the details code in xx12 to xxD0 xx=01: Y xx=02: M xx=03: C xx=04: Bk
T/D ratio is extremely high compared with when the new drum unit was installed.
Remedy: Replace the drum unit (check its connections).
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie