Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Canon iRC4080i

Code: E000-0001

Description: Insufficient temperature rise of fixing unit when power is turned ON
When the temperature of the fixing belt main thermistor failed to reach 50 deg C within 120 sec. after the fixing belt temperature regulation has started
Remedy: Check for broken or disconnected heater wires. Checking Disconnection of the Connector in the Thermistor Wiring. Replace the fixing belt unit. Replace the fixer. Replace the IH power supply PCB and AC driver PCB. Replace the DC controller PCB 2 (MAISY). In the service mode, clear the error by selecting COPIER > FUNCTION > CLEAR > ERR.

Code: E000-0101

Description: Insufficient temperature rise of fixing unit when power is turned ON
When the temperature of the pressure belt main thermistor failed to reach 50 deg C within 120 sec. after the pressure belt temperature regulation has started
Remedy: Check for broken or disconnected heater wires. Replace the fixing belt unit. Checking Disconnection of the Connector in the Thermistor Wiring. Replace the fixer and AC driver PCB. Replace the DC controller PCB 2 (MAISY). In the service mode, clear the error by selecting COPIER > FUNCTION > CLEAR > ERR.

Code: E001-0001

Description: Abnormally high temperature rise of fixing unit (circuit trouble)
When the fixing belt main thermistor has detected a high temperature (ASIC detection)
Remedy: Check the connection of the connector in the thermistor wiring (wirepinching, disconnection). Replace the fixing unit. Replace the IH unit, halogen heater, fixer and AC driver PCB. Replace the DC controller PCB 2 (MAISY). In the service mode, clear the error by selecting COPIER > FUNCTION > CLEAR > ERR.

Code: E001-0002

Description: Abnormally high temperature rise of fixing unit (circuit trouble)
When fixing sub-thermistor 1 has detected a high temperature (ASIC detection)
Remedy: Check the connection of the connector in the thermistor wiring (wirepinching, disconnection). Replace the fixing unit. Replace the IH unit, halogen heater, fixer and AC driver PCB. Replace the DC controller PCB 2 (MAISY). In the service mode, clear the error by selecting COPIER > FUNCTION > CLEAR > ERR.

Code: E001-0003

Description: Abnormally high temperature rise of fixing unit (circuit trouble)
When fixing sub-thermistor 2 has detected a high temperature (ASIC detection)
Remedy: Check the connection of the connector in the thermistor wiring (wirepinching, disconnection). Replace the fixing unit. Replace the IH unit, halogen heater, fixer and AC driver PCB. Replace the DC controller PCB 2 (MAISY). In the service mode, clear the error by selecting COPIER > FUNCTION > CLEAR > ERR.

Code: E001-0101

Description: Abnormally high temperature rise of fixing unit (circuit trouble)
When pressure main thermistor has detected a high temperature (ASIC detection)
Remedy: Check the connection of the connector in the thermistor wiring (wirepinching, disconnection). Replace the fixing unit. Replace the IH unit, halogen heater, fixer and AC driver PCB. Replace the DC controller PCB 2 (MAISY). In the service mode, clear the error by selecting COPIER > FUNCTION > CLEAR > ERR.

Code: E001-0102

Description: Abnormally high temperature rise of fixing unit (circuit trouble)
When pressure sub-thermistor 1 has detected a high temperature (ASIC detection)
Remedy: Check the connection of the connector in the thermistor wiring (wirepinching, disconnection). Replace the fixing unit. Replace the IH unit, halogen heater, fixer and AC driver PCB. Replace the DC controller PCB 2 (MAISY). In the service mode, clear the error by selecting COPIER > FUNCTION > CLEAR > ERR.

Code: E001-0103

Description: Abnormally high temperature rise of fixing unit (circuit trouble)
When pressure sub-thermistor 2 has detected a high temperature (ASIC detection)
Remedy: Check the connection of the connector in the thermistor wiring (wirepinching, disconnection). Replace the fixing unit. Replace the IH unit, halogen heater, fixer and AC driver PCB. Replace the DC controller PCB 2 (MAISY). In the service mode, clear the error by selecting COPIER > FUNCTION > CLEAR > ERR.
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin