Description: Tray up/down error
When the sensor is not reached even after 3000 ms when the standard tray was operated
Remedy: - Check the standard tray HP sensor connectors. - Check the standard tray clock sensor connectors. - Check the standard tray shift motor connectors. - Replace the standard tray HP sensor. - Replace the standard tray clock sensor. - Replace the standard tray shift motor. - Replace the finisher controller PCB.
Description: Tray up/down error
When the encoder clock signal of the standard tray is not detected for 2 or more times even after 300 ms when the standard tray was operated
Remedy: - Check the standard tray HP sensor connectors. - Check the standard tray clock sensor connectors. - Check the standard tray shift motor connectors. - Replace the standard tray HP sensor. - Replace the standard tray clock sensor. - Replace the standard tray shift motor. - Replace the finisher controller PCB.
Description: Tray up/down error
- When the tray fails to return to the home position even when the 1st tray shift motor has been driven for 20 sec. - When the tray fails to move to another area even when the 1st tray shift motor has been driven for 4 sec.
Remedy: - Check the 1st tray shift area sensor connectors. - Replace the 1st tray shift area sensor. - Replace the 1st tray shift motor (M107)
Description: Tray up/down error
When a danger area is reached before the sheet level is detected by the 1st tray sheet level detection sensor during the sheet level detection operation - When a discontinuous area was detected during the tray operation
Remedy: - Check the 1st tray shift area sensor connectors. - Replace the 1st tray shift area sensor. - Replace the 1st tray shift motor (M107)
Description: Tray up/down error
When the input of the clock signal could not be detected within 0.2 sec. during the operation of the 1st tray shift motor
Remedy: - Check the 1st tray shift area sensor connectors. - Replace the 1st tray shift area sensor. - Replace the 1st tray shift motor (M107)
Description: Tray up/down error
When the input of the clock signal could not be detected within 0.2 sec. during the operation of the 1st tray shift motor
Remedy: - Check the 1st tray shift area sensor connectors. - Replace the 1st tray shift area sensor. - Replace the 1st tray shift motor (M107)