Description: There is an error in the fixing assembly protection circuit. There is an open circuit or poor contact in the main thermistor (THM1, THM2, THM3) or sub thermistor (TH4, THM5, THM6). The AC driver PCB or the DC controller PCB has a fault.
The outside heating roller thermistor has an open circuit.
Remedy: Check the main thermistor and the sub thermistor for an open circuit and poor contact; then, reset in service mode: COPIER>FUNCTION>CLEAR>ERR.
Description: There is an error in the fixing assembly protection circuit. There is an open circuit or poor contact in the main thermistor (THM1, THM2, THM3) or sub thermistor (TH4, THM5, THM6). The AC driver PCB or the DC controller PCB has a fault.
The pressure roller thermistor has an open circuit.
Remedy: Check the main thermistor and the sub thermistor for an open circuit and poor contact; then, reset in service mode: COPIER>FUNCTION>CLEAR>ERR.
Description: There is an error in the take-up mechanism of the web.
The web of the fixing assembly has been fully taken up. After the web sensor has detected an off state, the count has exceeded 3000. The web length sensor (PS20) is faulty. The DC controller PCB is faulty.
Remedy: Reset in service mode: COPIER>FUNCTION>CLEAR>ERR. If you have replaced the web, reset the reading in the following, and turn off and then on the power: COPIER>COUNTER>DRBL-1>FIX-WEB.
Description: There is an outside heating roller shift error. The outside heating roller shift motor (M22) is faulty. The outside heating roller HP sensor (PS21) is faulty. The DC controller PCB is faulty.
The outside heating roller remains in contact with the fixing roller
Remedy: Check the outside heating roller shift motor and the fixing motor; then, turn off and then on the main power.