Code: E712-0000

Description: ADF/reader communication error
When communication between the reader and ADF was interrupted and 5 or more sec. have elapsed without communication having been restored
Remedy: Check the connector connections between the reader and ADF.

Code: E713-0004

Description: Finisher/printer communication error
When communication between the finisher and copier was interrupted
Remedy: Check the cable connections. Replace the finisher controller PCB. Replace the DC controller PCB.

Code: E716-0000

Description: Cassette pedestal/printer communication error
When trouble occurs in the data communication. When the DC controller or cassette pedestal controller PCB is defective
Remedy: Check the cable connections. Replace the pedestal PCB. Replace the DC controller PCB.

Code: E717-0001

Description: Error in communication with NE controller
When the NE controller which was connected before the power was turned OFF could not be recognized when the power was turned back ON
Remedy: Check the cable connections.

Code: E717-0002

Description: Error in communication with NE controller
When the IPC has a broken or disconnected wire or when an error has occurred where IPC communication cannot be recovered
Remedy: In the service mode, clear the error by selecting COPIER > FUNCTION > CLEAR > ERR.

Code: E719-0001

Description: Error in communication with coin vendor/card reader
When the coin vendor which was connected before the power was turned OFF could not be recognized when the power was turned back ON
Remedy: Check the cable connections.

Code: E719-0002

Description: Error in communication with coin vendor/card reader
- When a wire in the IPC cable connected with the coin vendor is broken or disconnected or when an error has occurred where IPC communication cannot be recovered - When a broken or disconnected wire in the sheet feed/delivery signal line was detected - When an illegal connection has been detected (when Tx and Rx of IPC have been short-circuited)
Remedy: In the service mode, clear the error by selecting COPIER > FUNCTION > CLEAR > ERR

Code: E719-0011

Description: Error in communication with coin vendor/card reader
When the card reader which was connected before the power was turned OFF could not be recognized when the power was turned back ON
Remedy: In the service mode, clear the error by selecting COPIER > FUNCTION > CLEAR > ERR