Mã lỗi Canon iRC5180i — Trang 7/27

Code: E020-xx24

Description: Concerning the first two digits of the details code in xx12 to xxD0 xx=01: Y xx=02: M xx=03: C xx=04: Bk
SALT sensor trouble or a broken/disconnected wire. There is trouble in the drum unit.
Remedy: Replace the SALT sensor (clean it). Check the drum unit connections. Replace the drum unit.

Code: E020-xx25

Description: Concerning the first two digits of the details code in xx12 to xxD0 xx=01: Y xx=02: M xx=03: C xx=04: Bk
SALT sensor trouble or a broken/disconnected wire. There is trouble in the drum unit. Deterioration in ITB.
Remedy: Replace the SALT sensor (clean the sensor window). Replace the drum unit (check its connections). Replace the ITB (clean it).

Code: E020-xx30

Description: Concerning the first two digits of the details code in xx12 to xxD0 xx=01: Y xx=02: M xx=03: C xx=04: Bk
ATR sensor trouble or a broken/disconnected wire. Incorrect setting of ATR sensor operation values. The drum unit is not installed properly or there is trouble in the unit.
Remedy: Replace the drum unit (check its connections).

Code: E020-xx34

Description: Concerning the first two digits of the details code in xx12 to xxD0 xx=01: Y xx=02: M xx=03: C xx=04: Bk
Sample images drawn by ATR control are not created. SALT sensor trouble or a broken/disconnected wire. There is trouble in the drum unit. Deterioration in ITB.
Remedy: Replace the SALT sensor (clean the sensor window). Replace the drum unit (check its connections). Replace the ITB (clean it).

Code: E020-xx35

Description: Concerning the first two digits of the details code in xx12 to xxD0 xx=01: Y xx=02: M xx=03: C xx=04: Bk
SALT sensor trouble or a broken/disconnected wire
Remedy: Replace the SALT sensor (clean it).

Code: E020-xx40

Description: Concerning the first two digits of the details code in xx12 to xxD0 xx=01: Y xx=02: M xx=03: C xx=04: Bk
Incorrect setting of ATR sensor operation values. ATR sensor trouble or a broken/disconnected wire. The drum unit is not installed properly (the copier cannot detect the drum unit) or there is trouble in the unit.
Remedy: Replace the SALT sensor (clean it). Replace the drum unit (check its connections).

Code: E020-xx50

Description: Concerning the first two digits of the details code in xx12 to xxD0 xx=01: Y xx=02: M xx=03: C xx=04: Bk
Incorrect developer density operation value which was set when the new drum unit was installed
Remedy: Replace the drum unit (check its connections).

Code: E020-xx60

Description: Concerning the first two digits of the details code in xx12 to xxD0 xx=01: Y xx=02: M xx=03: C xx=04: Bk
Incorrect developer density target value which was set when the new drum unit was installed (value is extremely low)
Remedy: Replace the drum unit (check its connections).