Code: E003-0002

Description: Fixing unit low temperature trouble
When the pressure main thermistor has detected a temperature below 50 deg C for the prescribed period of time after standby
Remedy: Checking Disconnection of the Connector in the Thermistor Wiring. Replace the fixing belt unit. Replace the fixer and AC driver PCB. Replace the DC controller PCB 2 (MAISY). In the service mode, clear the error by selecting COPIER > FUNCTION > CLEAR > ERR

Code: E004-0101

Description: Fixing unit protection circuit trouble
When there is a short-circuit detection error in the halogen heater (ASIC detection)
Remedy: Check the connection of the J114 jack of the AC driver PCB, and replace the AC driver PCB (triac short). Replace the Pressure heater. Replace the Fixing unit. Replace the DC controller PCB 2 (MAISY).

Code: E004-0201

Description: Fixing unit protection circuit trouble
When the difference in temperature between the front and back of the fixing belt is higher than the rating
Remedy: Replace the fixing belt unit. Replace the DC controller PCB 2 (MAISY).

Code: E004-0201

Description: Fixing unit protection circuit trouble
When the difference in temperature between the front and back of the fixing belt is higher than the rating
Remedy: Replace the fixing belt unit. Replace the DC controller PCB 2 (MAISY).

Code: E004-0202

Description: Fixing unit protection circuit trouble
When the difference in temperature between the center and front of the fixing belt is higher than the rating
Remedy: Replace the fixing belt unit. Replace the DC controller PCB 2 (MAISY).

Code: E004-0203

Description: Fixing unit protection circuit trouble
When the difference in temperature between the center and back of the fixing belt is higher than the rating
Remedy: Replace the fixing belt unit. Replace the DC controller PCB 2 (MAISY).

Code: E004-0204

Description: Fixing unit protection circuit trouble
When the difference in temperature between the front and back of the pressure belt is higher than the rating
Remedy: Replace the fixing belt unit. Replace the DC controller PCB 2 (MAISY).

Code: E004-0205

Description: Fixing unit protection circuit trouble
Thermistor temperature difference error (combination unknown)
Remedy: Replace the fixing belt unit. Replace the DC controller PCB 2 (MAISY).