Description: There is an error in the communication with the fixing feed PCB.
In the course of initializing communication between the DC controller and the fixing/feeding unit, as many as 10 communication errors occur continuously.
Remedy: Turn off the main power, and check the DC controller PCB wiring and the 24V system fuse; then, turn on the main power.
Description: There is an error in the communication with the fixing feed PCB.
Following the end of initialization of the communication between the DC controller and the fixing/feeding unit, as many as 10 communication errors occur continuously.
Remedy: Turn off the main power, and check the DC controller PCB wiring and the 24V system fuse; then, turn on the main power.
Description: There is an error in the communication with the fixing feed PCB.
At the start of drum initial multiple rotation, there is no signal indicating the start of 24V in the fixing assembly in the communication between the DC controller and the fixing/feeding unit.
Remedy: Turn off the main power, and check the DC controller PCB wiring and the 24V system fuse; then, turn on the main power.
Description: There is an HP error.
An error is found during the forward trip of the HP search. The scanner HP sensor is faulty. The scanner motor is faulty. The reader controller is faulty.
Remedy: Check the harness connector for connection; then, as necessary, replace the faulty part.
Description: There is an HP error.
An error is found during the return trip of the HP search. The scanner HP sensor is faulty. The scanner motor is faulty. The reader controller PCB is faulty.
Remedy: Check the harness connector for connection; then, as necessary, replace the faulty part.