Description: Reboot instruction initiated by change in PDL configuration
A change has occurred that calls for turning off and then on the power.
Remedy: Turn off and then on the power.
Code: E800-0001
Description: The interlock 24V mechanism of the fixing unit is identified as being off. With the door closed, the interlock 24V mechanism remains off for 500 msec.
Remedy: Turn off the main switch, and check the wiring of the DC controller PCB, check the fixing unit interlock, and check the 24V system fuse; then, turn on the interlock main switch.
Code: E804-0004
Description: There is any of the various types of fan errors.
There is an error in the controller cooling fan.
Remedy: Turn off the main switch, and check the wiring of the DC controller PCB and the 24V system fuse; then, turn on the main switch.
Code: E804-0007
Description: There is any of the various types of fan errors.
There is an error in the power supply cooling fan.
Remedy: Turn off the main switch, and check the DC controller PCB and the 24V system fuse; then, turn on the main switch.
Code: E805-0003
Description: The fixing heat exhaust fan is identified as having stopped or having an error.
There is an error in the fixing heat exhaust fan.
Remedy: Turn off the main power, and check the supply of power to the fan; then, as necessary, replace the fan, and turn on the main power.
Code: E820-0002
Description: There is an error in the process unit cooling fan.
There is an error in the process unit fan.
Remedy: Turn off the main switch, and check the wiring of the DC controller PCB and the 24V system fuse; then, turn on the main switch.
Code: E824-0000
Description: There is an error in the primary charging suction/primary charging exhaust fan.
There is an error in the primary charging suction mechanism.
Remedy: Turn off the main power, and check the DC controller PCB and the 24V system fuse; then, turn on the main switch.
Code: E824-0001
Description: There is an error in the primary charging suction/primary charging exhaust fan.
There is an error in the primary exhaust fan.
Remedy: Turn off the main switch, and check the wiring of the DC controller PCB and 2V system fuse; then, turn on the main switch.