Description: There is an ATR error. xx=01 for Y; xx=02 for M; xx=03 for C; xx=04 for without color distinction
When the background (intermediate transfer belt) is read during patch detection, the P_base_adj value is lower than 255. The ATR sensor is damaged or has an open circuit. The connector has poor contact. The ITB cleaner is faulty.
Remedy: Turn off and then on the main power; then, execute the intermediate transfer belt.
Description: There is an ATR error. xx=01 for Y; xx=02 for M; xx=03 for C; xx=04 for without color distinction
The result (Sig D) of computation based on the reading of the patch during patch detection (analog)) is lower than 16.
Remedy: Turn off and then on the main power; then, execute the intermediate transfer belt.
Description: There is an ATR error. xx=01 for Y; xx=02 for M; xx=03 for C; xx=04 for without color distinction
The result (Sig D) of computation based on the reading of the patch during patch detection (analog) is 1008 or higher. The patch sensor is damaged or has an open circuit. The connector has poor contact. The primary transfer pressure is faulty. The mounting of the developing assembly is faulty.
Remedy: Turn off and then on the main power; then, execute the intermediate transfer belt.
Description: There is an ATR error. xx=01 for Y; xx=02 for M; xx=03 for C; xx=04 for without color distinction
The value delta D obtained from the result (Sig D) of computation based on the reading of the patch during patch detection is -5.0% or more 3 times continuously. The patch sensor may be damaged or has an open circuit. The connector has poor contact. The primary transfer engagement is faulty. The mounting of the developing assembly is faulty. The amount of supply is low.
Remedy: Turn off and then on the main power; then, execute the intermediate transfer belt.
Description: There is an ATR error. xx=01 for Y; xx=02 for M; xx=03 for C; xx=04 for without color distinction
The value delta D obtained from the result (Sig D) of computation based on the reading of the patch during patch detection is +5.0% or lower 3 times continuously. The patch sensor is damaged or has an open circuit. The connector has poor contact. The primary transfer pressure is faulty. The mounting of the developing assembly is faulty. The amount of supply is low.
Remedy: Turn off and then on the main power; then, execute the intermediate transfer belt.
Description: There is an ATR error. xx=01 for Y; xx=02 for M; xx=03 for C; xx=04 for without color distinction
For ATR control, the Sig value is lower than 62. The ATR sensor is damaged or has an open circuit. The connector has poor contact.
Remedy: Turn off and then on the main power; then, execute the intermediate transfer belt.
Description: There is an ATR error. xx=01 for Y; xx=02 for M; xx=03 for C; xx=04 for without color distinction
For ATR control, the Ref value is lower than 62. The ATR sensor is damaged or has an open circuit. The connector has poor contact.
Remedy: Turn off and then on the main power; then, execute the intermediate transfer belt.
Description: There is an ATR error. xx=01 for Y; xx=02 for M; xx=03 for C; xx=04 for without color distinction
For ATR control, the Ref value is lower than 62. The ATR sensor is damaged or has an open circuit. The connector has poor contact.
Remedy: Turn off and then on the main power; then, execute the intermediate transfer belt.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.