Code: E043-0001

Description: There is an error in the 3.5K paper deck pickup motor, causing an error signal.
After motor start-up, a lock state is not detected for 1 sec or more. The mechanical load such as on the feeding system is excessive.
Remedy: Turn off and then on the main power.

Code: E051-0001

Description: The horizontal registration home position is not detected within a specific period of time. The horizontal registration position is faulty (0003).
The horizontal registration home position is not detected within a specific period of time.
Remedy: Turn off and then on the main power.

Code: E051-0002

Description: The horizontal registration home position is not detected within a specific period of time. The horizontal registration position is faulty (0003).
The ON edge of the SUS plate is not detected during a search for home position.
Remedy: Turn off and then on the main power.

Code: E051-0003

Description: The horizontal registration home position is not detected within a specific period of time. The horizontal registration position is faulty (0003).
The logical motor position differs between before and after the detection operation.
Remedy: Turn off and then on the main power.

Code: E061-0001

Description: At time of potential control, a specific level of potential is absent. Or, the limiter goes on.
When forming an image, the potential is 10 V or less during initial rotation.
Remedy: Turn off and then on the main power.

Code: E061-0002

Description: At time of potential control, a specific level of potential is absent. Or, the limiter goes on.
At time of potential control, the potential is 10 V or less during initial rotation
Remedy: Turn off and then on the main power.

Code: E061-0003

Description: At time of potential control, a specific level of potential is absent. Or, the limiter goes on.
While the grid bias is being adjusted, a level of potential higher than the grid bias is sampled.
Remedy: Turn off and then on the main power.

Code: E061-0005

Description: At time of potential control, a specific level of potential is absent. Or, the limiter goes on.
The difference in potential between dark and light areas is less than 100 V.
Remedy: Turn off and then on the main power.